Ads by Google
Switching Power Supply With PFC Function SP-150
1) Features:
Universal AC input / full rangeBuilt-in active PFC function, PF>0.93Protections:Short circuit/Over load/Over voltage/Over temperatureBuilt-in constant current limiting circuitRemote ON-OFF control(Optional)LED indicator for power on100% full load burn-in testFixed switching frequency at PFC:67KHz PWM:134KHz1 year warranty2) Switching Power Supply With PFC Function SP-150 Specification:
MODEL | SP-150-3.3 | SP-150-5 | SP-150-7.5 | SP-150-12 | SP-150-13.5 | SP-150-15 | SP-150-24 | SP-150-27 | SP-150-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
RATED CURRENT | 30A | 30A | 20A | 12.5A | 11.2A | 10A | 6.3A | 5.6A | 3.2A | |
CURRENT RANGE | 0 ~ 30A | 0 ~ 30A | 0 ~ 20A | 0 ~ 12.5A | 0 ~ 11.2A | 0 ~ 10A | 0 ~ 6.3A | 0 ~ 5.6A | 0 ~ 3.2A | |
RATED POWER | 99W | 150W | 150W | 150W | 151.2W | 150W | 150W | 151.2W | 153.6W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 250mVp-p | |
VOLTAGE ADJ. RANGE | 3.14 ~ 3.63V | 4.75 ~ 5.5V | 7.13 ~ 8.25V | 11.4 ~ 13.2V | 12.8 ~ 14.9V | 14.3 ~ 16.5V | 22.8 ~ 26.4V | 25.7 ~ 29.7V | 45.6 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE, HOLD TIME | 600ms, 30ms, 20ms at full load | |||||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
POWER FACTOR (Typ.) | PF>0.93/230VAC PF>0.98/115VAC at full load | |||||||||
EFFICIENCY (Typ.) | 67% | 75% | 79% | 80% | 80% | 81% | 83% | 84% | 84% | |
AC CURRENT(Typ.) | 2.5A/115VAC 1.2A/230VAC | |||||||||
INRUSH CURRENT (Typ.) | COLD START 40A/230VAC | |||||||||
LEAKAGE CURRENT | <2mA / 240VAC | |||||||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | ||||||||
Protection type: Constant current limiting, recovers auto matically after fault condition is removed | ||||||||||
OVER VOLTAGE | 3.63 ~ 4.46V | 5.5 ~ 6.75V | 8.25 ~ 10.13V | 13.2 ~ 16.2V | 14.85 ~ 18.23V | 16.5 ~ 20.25V | 26.4 ~ 32.4V | 29.7 ~ 36.45V | 52.8 ~ 64.8V | |
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||||
FUNCTION | REMOTE CONTROL (OPTION) | CN1: 4 ~10VDC POWER ON, <0 ~ 0.8VDC POWER OFF | ||||||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.05%/ºC (0 ~ 50ºC) | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC(Note4) | SAFETY STANDARDS | Design refer to UL60950-1, TUV EN60950-1 | ||||||||
WITHSTAND VOLTAGE | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022(CISPR22) Class B | |||||||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | |||||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11;EN50204,EN55024,Light industry level, criteria A | |||||||||
OTHERS | MTBF | 211.3K hrs min. MIL-HDBK-217F (25ºC) | ||||||||
DIMENSION | 179*99*45mm (L*W*H) | |||||||||
PACKING | 0.578Kg; 30pcs/19.24Kg/0.0250CBM | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.5. derating may be needed under low input voltages.Plase check the derating curve for more details. |
3) Mechanical Specification:
4) Production Capacity & Quality Control:
5) Switching Power Supply With PFC Function SP-150 LVD Certificate:
6) EMC Certificate: