LED Driver | SP-350-24 | |
OUTPUT | DC VOLTAGE | 24V |
RATED CURRENT | 14.6A | |
CURRENT RANGE (convection) | 0~12.5A | |
CURRENTRANGE(23.5CFMFAN) | 0~14.6A | |
RATED POWER (convection) | 300w | |
RATEDPOWER (23.5CFM FAN) | 350.4W | |
RIPPLE & NOISE (max.) Note.2 | 150MVP-P | |
VOLTAGEADJ.RANGE | 21.6~26.4V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | |
LINEREGULATION | ±0.5% | |
LOADREGULATION | ±1.0% | |
SETUP,RISE TIME | 2000ms, 100ms/230VAC 4000,100ms/115VAC at full load | |
HOLD,TIME(TYP.) | 16ms/230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGERANGE | 90~264VAC 127~370VDC |
FREQUENCYRANGE | 47~63HZ | |
POWER FACTOR (Typ.) | 0.95/230VAC 0.98/115VAC at full load | |
EFFICIENCY (Typ.) | 88% | |
AC CURRENT (Typ.) | 4A/115VAC 2A/230VAC | |
INRUSH CURRENT (Typ.) | 22A/115VAC 44A/230VAC | |
LEAKAGECURRENT | <2mA/240VAC | |
PROTECTION | OVERLOAD | 105~130%rated output power |
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 26.7~32.4V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | 80~±5(TSW1) detect on heatsink of power transistor 80~±5(TSW2 ) detect on heatsink of power diode | |
Protection type : Shut down o/p voltage with auto-recovery | ||
ENVIRONMENT | WORKING TEMP. | -10~+65 (refer to output load derating curve) |
WORKING HUMIDITY | 20~90% RH non-condensing | |
STORAGE TEMP HUMIDITY | -40~+85 10~95%RH | |
TEMPCOEFFICIENT | ±0.03%(0~45) | |
VIBRATION | 10~500HZ,2G10min/1cycle,60min.each alongX,Y,Zaxes | |
SAFETY&EMC | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 APPROVED |
WITHSTAND VOLTAGE | 1/P-0/P:3KVAC 1/P-FG:1.5KVAC 0/P-FG:0.5KVAC | |
ISOLATIONRESISTANCE | 1/P-0/P,1/P-FG,0/P-FG:100M Ohms/500VDC | |
EMI CONDUCTICN& RADIATION | Compliance to EN55022(CISPR22)classB | |
HARMONICCURRENT | Compliance to EN61000-3-2,-3 | |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204,EN55024, Light industry level criteriaA | |
QTHERS | MTBF | 106.3Khrs min MIL-HDBK-217F(25) |
DIMENSION | 235.2*101.5*38mm(L*W*H) | |
PACKING | 1.1g ;16pcs / 18Kg / 0.72CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. |