Meanwell Parallel,PFC switching power supply UL,CE,CB certificates Parallel and PFC function 3 years warranty with DC fan

MODEL

PSP-600-15

OUTPUT

DC VOLTAGE

15V

CURRENT RANGE

0 ~ 40A

RATED CURRENT

40A

RATED POWER

600W

RIPPLE & NOISE (max.) Note.2

240mVp-p

VOLTAGE ADJ. RANGE

13.5 ~ 18V

VOLTAGE TOLERANCENOTE.3

1.0%

LINE REGULATION

0.5%

LOAD REGULATION

0.5%

SETUP, RISE TIME

1500ms, 50ms at full load

HOLD UP TIME (Typ.)

20ms at full load

INPUT

VOLTAGE RANGE

88 ~ 264VAC 124 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)?

0.95/230VAC 0.99/115VAC at full load

EFFICIENCY (Typ.)

85%

AC CURRENT (Typ.)

6.8A/115VAC 3.4A/230VAC

INRUSH CURRENT (Typ.)

20A/115VAC 40A/230VAC

LEAKAGE CURRENT

<1.3mA/240VAC

PROTECTION

OVER LOAD

105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

OVER VOLTAGE

18 ~ 21V

Protection type : Shut down o/p voltage,fe-power on to tecovery

OVER TEMPERATURE

+5V: 95 (TSW1) detect on heatsink of power transistor; 95 (TSW51) detect on heatsink of power diode

+12V ~ +48V: 85 (TSW1) detect on heatsink of power transistor; 80 (TSW51) detect on heatsink of power diode

Protection type : Shut down o/p voltage,fe-power on to tecovery

REMOTE CONTROL

RC+/RC-: Short = power on ; Open = power off

POK SIGNAL

PSU turn on: 3.3V ~ 5.6V PSU turn off: 0V ~ 1V

ENVIRONMENT

WORKING TEMP.

-20 ~ +60°C (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85°C , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/°C (0 ~ 50°C )

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for? 60min. each along X, Y, Z axes

SAFETY &EMC(Note 4)

SAFETY STANDARDS

UL60950-1, TUV EN60950-1 approved

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH

EMI CONDUCTION & RADIATION

Compliance to EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2,-3

EMS IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A

OTHERS

MTBF

116.4K hrs min. MIL-HDBK-217F (25 )

DIMENSION

170*120*93mm (L*W*H)

PACKING

1.9Kg; 8pcs/15.5Kg/1.06CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°Cof ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives.5. Derating may be needed under low input voltages. Please check the derating curve for more details.