4. Protections: Short circuit / Over load / Over voltage5. Cooling by free air convection6. Fixed switching frequency at 50KHz7. 2 years warranty8. Dimensions: 159*97*38mm(L*W*H) |
Specification: |
Model | S-60-5 | S-60-12 | S-60-15 | S-60-24 | S-60-48 | |
Output | DC voltage | 5V | 12V | 15V | 24V | 48V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | |
Rated current | 12A | 5A | 4A | 2.5A | 1.3A | |
Current range | 0-12A | 0-5A | 0-4A | 0-2.5A | 0-1.3A | |
Rated power | 60W | 60W | 60W | 60W | 62.4W | |
Ripple & noise | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | |
DC adjustment range | +10, -5% | ±10% | ±10% | ±10% | ±10% | |
Setup, rise, hole time | 800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC | |||||
Input | Voltage range | 85~264 VAC 47~63 Hz;120~370VDC | ||||
AC current | 2A/115 V 1A/ 230 V | |||||
Efficiency | 73% | 76% | 77% | 79% | 80% | |
Inrush current | Cold start 30A/115VAC 60A/230VAC | |||||
Leakage current | ||||||
Protection | Over load | 135%~165% | ||||
Protection type: Fold back current limiting, recovers automatically after fault condition is removed. | ||||||
Over voltage | 115%~135% | |||||
Protection type: hiccup mode, recovers automatically after fault condition is removed. | ||||||
Environment | Working temp. & humidity | -10°C~+60°C;20%~90 %RH | ||||
Storage temp. & humidity | -20°C~+85°C;10%~95 %RH | |||||
Vibration | 10~500Hz,2G 10min./1cycle,period for 60min, each long X, Y, Z, axes | |||||
Safety | Withstand voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | ||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||
Standard | Safety standard | Design refer to UL1012, UL1950,TUV EN60950 | ||||
EMC standard | Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 | |||||
Others | Weight | 0.51Kg | ||||
Packing | 24pcs/13.1Kg/0.7CUFT | |||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |