4. Cooling by free air convection5. LED indicator for power on 6. Fixed switching frequency at 27KHz7. 1 year warranty8. Dimensions: 159*97*38mm(L*W*H) |
Specification: |
Model | S-50-5 | S-50-12 | S-50-15 | S-50-24 | S-50-48 | |
Output | DC voltage | 5V | 12V | 15V | 24V | 48V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | |
Rated current | 10A | 4.2A | 3.4A | 2.1A | 1A | |
Current range | 0-10A | 0-4.2A | 0-3.4A | 0-2.1A | 0-1A | |
Rated power | 50W | 50.4W | 51W | 50.4W | 48W | |
Ripple & noise | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
DC adjustment range | +10,-5% | ±10% | ±10% | ±10% | ±10% | |
Setup, rise, hold time | 200ms,100ms,20ms at full load | |||||
Input | Voltage range | 85~132 VAC/170~264VAC 47~63 Hz;Choice 240~370VDC | ||||
AC current | 1.3A/115 V 0.65A/ 230 V | |||||
Efficiency | 71% | 78% | 78% | 82% | 84% | |
Inrush current | Cold start18A/115V 36A/230V | |||||
Leakage current | ||||||
Protection | Over load | 110%~160% | ||||
Protection type: Fold back current limiting, recovers automatically after faultlt condition is removed | ||||||
Environment | Working temp. & humidity | -10°C~+60°C;20%~90 %RH | ||||
Storage temp. & humidity | -20°C~+85°C;10%~95 %RH | |||||
Vibration | 10~500Hz,2G 10min./1cycle,period for 60min, each along X, Y, Z axes | |||||
Safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||
Standard | Safety standard | Design refer to UL1012 | ||||
EMC standard | Design refer to FCC Part15 J Conduction Class B | |||||
Others | Weight | 0.51Kg | ||||
Packing | 24pcs/13.1Kg/0.7CUFT | |||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. |