Addressable input module; Capacity of the output control contact: 2A@DC30V Weight: about 130g Fire Alarm Control System Addressable Input Module Features andTechnical parameters1. Mode of operation ... -down mode)3. Action current: <10mA4. Capacity of the output control contact: 2A@DC30V5. Operation indicator: The inspection indicator will blink ...
Addressable Fire Alarm Control Panel,is also called fire alarm control panel,fire alarm panel and panel. Key Words: fire alarm control panel, fire alarm, fire alarm panel, FACP, addressable fire alarm control panelProduct OverviewThe OZH4800E control panel is an ... systems can be established by using a conventional zone-monitoring module. The basic system can be expanded by adding OZF-LCD ...
fire alarm control panel 1) Conventionalv Fire Alarm Control Panel 2)4.8.16 zone 3) 24 Volt Operated fire detection system fire alarm control panel(1) 4.8.16 zone ... ) Alarm, Trouble and Supervisory, Form-C relays standard. (4) 24-volt operation. (5) Disable/Enable control per IDC. (6) Reverse polarity protection. fire alarm control ...
... Wall-mounted, easy to use 4.Sorted data records electrical fire alarm control panelFeatures:1. HBUS bus communication technology, with automatic protection function ... 's XG100 graphical monitor system. 6. With remote control function ,can control remote controller by manually or automatically. 7.With remote ... ,XE3123, XE3124,XE3125, XE3126 128 point graphic display electrical fire alarm control panel
... . 16 zones Addressable wired fire alarm control panel alarm panel accept two-wire smoke detectors >>>>Specificationsfire alarm control panel 1) Conventionalv Fire Alarm Control Panel 2)4.8.16 ... zone 3) 24 Volt Operated fire detection systemfire alarm control panel(1) 4 ...
... no need for active E 1 to 16 zone conventional fire alarm control panel Microprocessor based Detector removal line integrity (no need for ... Battery charger short circuit protection Zone short circuit protection Fire change over relay output Fault change over relay output ... = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); FIRE ALARM SYSTEM CONTROL PANEL
Wireless fire alarm system (wireless detector, control panel) 1.32 protection zone Wireless fire alarm system (wireless detector, control panel) 1. No wiring is required and ... storedcircularly with alarm message when alarm is triggered10.Mute or audible alarm is at users option11.Long distance arm/disarm control to the ... approved,conform to UL864 standard,BV ISO9001:2000 Wireless fire alarm system
Shield Alarm cable Competitive price; PVC insulated; Flame retardancy and other enhanced features available ISO Shield Alarm cableInsulation:PVC, or PVC of flame retardant and other property.Sheath:PVC, or PVC of flame retardant and other property.Voltage rating: 450/750, 600/1000v Fire Alarm Cable
... 22awg, 2 conductor for alarm industry and with flame resistant FT-4 for intruder alarm systems. Fire alarm and security cable 22awg, ... 2 conductor for alarm industry and with flame resistant ... sepcification are available on demand. Fire alarm and security cable 22awg, 2 conductor for alarm industry and with flame resistant ...
... PVC Jacket 3)PVC Flame Retarant insulation 4)OEM Welcome Alarm control Cable Applications:Wiring Burglar and Security alarms, public address ... telephone stations, speakers,instrumentation, control and other low voltage circuits that are power limited.Specification:Alarm Cable Unshielded 4*0.22mm2 ... Voltage 50V PVC - Polyvinylchlorid TC - Tinned Copper Security Alarm control Cable 4 Core unshield
... RF Transmitter/Receiver module used extensively in the garage, shutter and automatic door, remote sensing telemetry, industrial control and communication areas.First ... worldwide clients, and wish our efforts bring you best satisfaction! Fire alarm Heat & Smoke Detector Fire Detector smoke detector gas detector codetector home ...
wireless fire alarm Model: PST-GSM-02(A) The SMS content can be changed; SMS control; Auto dial wireless fire alarmName: GSM Home Alarm System with ... GSM module.With color LCD show screen and keyboard on the host.11 wireless guarding zones (1 wireless SOS zone, 1 fire alarm ...
... , emergency start / stop buttons, can control the linkage equipment independently. Aerosol fire control panel has the inspection and alarm function of the external circuit ... and reliable function. The control panel can easily access to the intelligent system of the building by the module, to become a ...
... 4,ISO9001,CE Certified AC Fire CPS Control and Protective Switching SPKBO-F Module structure and integrate with main ... conditions including specified overloading and over current to realize " alarm only, not trip" function, can also switch on ... circuit current, to realize " alarm+trip" function. Characteristics and main parametersSPKBO-F Fire Control and Protective Switching Device adopts operation ...
... and remote, lock unlock door with mobile phone, receive alarm information withmobile phone, locate current location and upload to ... with duplicated carkey), you need install the bypass RFID control module to pass ID key checking before startcar engine by ... metersProduct Original Pictures:GSM bypass Module :GSM Car Alarm Start Modes:Installation Instruction:GSM Car Alarm Wire Diagram:Attention:1) By ...
1, economic fire alarm 2, to detect the smoke and fire 3, smoke detector 4, CE for alarm system fire alarm1, economic fire alarm2, to detect the ... for alarm systemProduct Name : wireless / wire fire alarmModel: VIP-909Technical Data1. 9V spare replaceable battery 2. Special protection design of wiring module 3 ... degreeOperating Humidity: <95% RHAlarm Output: sound alarmSensitivity: I or II fire alarm
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.