Coating Thickness Gauge
F1 probe ( Can match with MT2100,MT3100,MT4100)
F1 probe adopted magnetic method. It can measure the thickness of non-magnetic coatings ( e.g. zinc, aluminum, Cr. Copper, rubber, paint and etc.) on magnetic metallic base ( such as steel, iron, alloy and hard magnetic steel etc.)
Measuring Principles: magnetic
Measuring Range : 0-1250um
Measuring Accuracy(um) :One point calibration : ±(3%H+1)
Two points calibration : ±(1%H+1)
Lower Limitation Resolution : 0.1
Minimum curvature radius (protrude) : 1.5
Minimum area diameter:φ7
Base critical thickness :0.5
F400 Probe (Can match with MT3100/4100)
F400 probe adopted magnetic method. It can measure the thickness of non-magnetic coatings ( e.g. zinc, aluminum, Cr. Copper, rubber, paint and etc.) on magnetic metallic base ( such as steel, iron, alloy and hard magnetic steel etc.)
Measuring Principles: magnetic
Measuring Range : :0-400um
Measuring Accuracy(um) :One point calibration : ±(3%H+0.7)
Two points calibration : ±(1%H+1)
Lower Limitation Resolution :0.1
Minimum curvature radius (protrude) : 1
Minimum area diameter:φ3
Base critical thickness :0.2mm
F10 Probe (Can match with MT3100/4100)
F10 probe adopted magnetic method. It can measure the thickness of non-magnetic coatings ( e.g. zinc, aluminum, Cr. Copper, rubber, paint and etc.) on magnetic metallic base ( such as steel, iron, alloy and hard magnetic steel etc.)
Measuring Principles: magnetic
Measuring Range :0- 10mm
Measuring Accuracy(um) :One point calibration : ±(3%H+10)
Two points calibration : ±(1%H+10)
Lower Limitation Resolution : 1
Minimum curvature radius (protrude) : 10
Minimum area diameter:φ40
Base critical thickness : 2mm
F1/90 Probe (Can match with MT3100/4100)
F1/90 probe adopted magnetic method. It can measure the thickness of non-magnetic coatings ( e.g. zinc, aluminum, Cr. Copper, rubber, paint and etc.) on magnetic metallic base ( such as steel, iron, alloy and hard magnetic steel etc.)
Measuring Principles: magnetic
Measuring Range : 0-1250um
Measuring Accuracy(um) :One point calibration : ±(3%H+1)
Two points calibration : ±(1%H+1)
Lower Limitation Resolution :0.1
Minimum curvature radius (protrude) : Straightness
Minimum area diameter:φ7
Base critical thickness : 0.5mm
N1Probe (Can match with MT2100N/ MT3100/4100)
N1 probe adopted eddy current method. It can measure the all electrically insulating coating layers thickness (such as lacquer,Varnish, paint,anodizing) coating on non-ferrous metals (such as copper, Al, Zinc and etc) and also on austenitic VA steel materials.
Measuring Principles: Eddy current method
Measuring Range : 0-1250um
Measuring Accuracy(um) :One point calibration : ±(3%H+1.5)
Two points calibration : ±(1%H+1.5)
Lower Limitation Resolution :0.1
Minimum curvature radius (protrude) :3
Minimum area diameter:φ5
Base critical thickness : 0.3mm
N400 Probe (Can match with MT3100/4100)
N400 probe adopted eddy current method. It can measure the all electrically insulating coating layers thickness (such as lacquer,Varnish, paint,anodizing) coating on non-ferrous metals (such as copper, Al, Zinc and etc) and also on austenitic VA steel materials.
Measuring Principles: Eddy current method
Measuring Range : 0-400um
Measuring Accuracy(um) :One point calibration : ±(3%H+1)
Two points calibration : ±(1%H+1)
Lower Limitation Resolution :0.1
Minimum curvature radius (protrude) :1.5
Minimum area diameter:φ4
Base critical thickness : 0.3mm