Load cell Good quality with low price high quality

Rated load (kg):3,5,6,10,15,20,30,40,50,60,100,120Main features:The product is made of alloy aluminum. It is hermetically sealed with glue to IP65, surface anodized and anti-corrosion, integral structure and easy installation. The product is suit for electronic top scale, floor scale and other weighing equipment.

 

Parameters:

Precision : C2/C3

 

Temp. effect on span(%F.S/10°C): ±0.02/±0.014

Comprehensive error(%F.S) : ±0.02/±0.017

 

Temp. effect on zero(%F.S/10°C) : ±0.03/±0.017

Rated output(mv/v) : 2.0±0.2

 

Compensated temp. range(°C ) : -10~+40

Creep(%F.S/30min) : ±0.02/±0.017

 

Use temp. range(°C ) : -20~+60

Zero balance(%F.S) : ±1.0

 

Excitation voltage(V) : 9~12(DC)

Input resistance(Ω) : 405±10

 

Safe overload (%F.S) : 120

Output resistance(Ω) : 350±3

 

Ultimate overload (%F.S) : 150

Insulation resistance(MΩ) : ≥5000(100VDC)

 

Defend grade : IP65

 

Installation size (mm):

 

  

Wiring schematic diagram:

Red: Input ( + )111   White: Output ( - )Black: Input ( - )111Green: Output ( + ) Notes:It used 4-core shielded cable(φ5×3000mm)