Welcome to ECOL - Join Free - Sign In
ETCR4200A Double Clamp /Three Phase Digital Phase Meter ----Manufactory, RS232 interface
ETCR4200A Double Clamp /Three Phase Digital Phase Meter ----Manufactory, RS232 interface
Supplier Info
[China Supplier]
Contact Person : Ms. Su Lili
Tel : 86-020-62199556
Fax : 86-020-62199550
Product Detail
Double Clamp /Three Phase Digital Phase Meter 1.measure AC voltage,current,phase,frequency,phase sequence,power 2.RS232

 

 ETCR 4200A Double Clamp /Three Phase Digital Phase Meter

 

 

Features:Simultaneously measure two AC voltage, current, phase, frequency, phase sequence, power, power factor. Clamp Size: 35×40mm, Phase: 0~360°, AC Current: 0.0mA~20.0A, AC Voltage: 0.00 V~600V, Active Power: 0.0W~12kW, with RS232 interface to download data, Date Storage: 1500 sets..Technical Specifications
FunctionSimultaneous measurement of two AC voltage, current, phase between voltage, phase between current, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, distinguish transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc.
PowerDC9V alkaline batteries(1.5V AA×6)
ConsumptionAbout 70mA at most with enabled backlight, battery working continuously for about 14hours
About 40mA with disabled backlight, battery working continuously for about 20hours
Display ModeLCD display, 240dots×160dots
Meter SizeLength, Width, Height:196mm×92mm×54mm
Clamp Sizeround current clamp:35mm×40mm
Measurement Range(automatic shift)AC Voltage:0.00V~600V(automatic shift)
AC Current:0.0mA~20.0A (automatic shift)
Phase:0~360°
Frequency:45.00Hz~65.00Hz
Active Power:0.0W~12kW
Reactive Power:0.0W~12kVAR
Apparent Power:0.0W~12kVA
Power Factor:-1~+1
ResolutionVoltage:AC 0.01V
Current:AC 0.1mA
Phase:0.1°
Frequency:0.01Hz
Active Power:0.1W
Reactive Power:0.1VAR
Apparent Power:0.1VA
Power Factor:0.001
Sampl e RateAbout 2times/second
Data HoldPress HOLD key to keep data, " DH " symbol appears
Data Storage1500 sets
RS232 InterfaceUSB-RS232 interface, download data to computer for analysis and management
Automatic ShutdownAutomatic shutdown about 15 minutes later after launching to reduce battery consumption
BacklightingSuitable for dark place and nightly use
Voltage DetectionLow battery symbol “     " appears to remind the replacement of battery when the battery voltage drops below 7.2V.
WeightMain Unit about 550g(with battery),acuminate current clamp about 170g×3, roundcurrent clamp about 185g×3, test line about 250g
Test Line Length1.5m
Current Clamp Length2m×φ5mm
Working Temperature and Humidity-10°C~40°C;below 80%Rh
Storage Temperature and Humidity-10°C~60°C;below 70%Rh
Input ImpedenceTesting voltage the input impendence is 2MΩ
Withstand VoltageWithstand 1000V/50Hz sine wave AC voltage for 1 minute between the meter lines and shell; Withstand 500V/50Hz AC voltage sine wave for 1 minute between the two voltage inputs
Insulation≥100MΩbetween meter lines and shell or between the two voltage inputs
StructureDouble insulation, with insulation vibration-proof sheath
S afety S pecificationsIEC61010-1 CAT Ⅲ600V, IEC61010-031, IEC61326, 2 class of pollution
AccessoriesMain Unit: 1pc; Meter Box: 1piece; Current Clamp: 3 pcs; Test Line: 4pcs(2 yellow, 2black); RS232 Data Line: 1 pc; Disk: 1 pc; Battery: 6pcs( alkaline dry battery : 1.5V AA); User Manual: 1 pc; Guarantee Card : 1 pc; Certification: 1 pc.
.Field Application

1. Single-phase test 

2. Three-phase four-wire test

3. Three-phase three-wire test

 

 

ETCR4200A Double Clamp /Three Phase Digital Phase Meter ----Manufactory, RS232 interface

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.