Welcome to ECOL - Join Free - Sign In
Valve Steam 1''-4''
Valve Steam 1''-4''
Supplier Info
[China Supplier]
Contact Person : Ms. Weng Kitty
Tel : 86-21-62441919
Fax : 86-21-62442188
Product Detail
used in HVAC 0-10VDC 2-10VDC 4-20mA to choose ball valve steam screw or flange type temperature medium: -10 to 180 degree C

The QM/QF series of electric valve actuators are used in heating, ventilation, and air-conditioning (HVAC) applications. The QM series of electric valve actuators are modulating control actuators  used with controls that provide an analog output of 0 to 10Vdc, 2 to 10Vdc or 4-20mA. The internal selector plug can be used to reverse the direction of action. The QF series of electric valve actuators are controlled by an on/off output.

FEATURES

 Low power consumption

 Position feedback by signal

 Direct/reverse acting

 4-20mA/0-10V/2-10V choice

 Maintenance free

 Quick and easy installation

 No separate linkage required

 Accurate valve positioning

 Indicator Continuous Position Indicator      

 Manual Override Non-clutch design     

 Gear Permanently lubricated and self locking      

 Stall Protection Built-in thermal protection   

MODEL NUMBER DESCRIPTIONS

VALVE 

Flow media

Cold and hot water, water with max. 50% volume of glycol

Temperature of medium

-10°C.. +180°C

Rated pressure

1600 / 2760kPa

Leakage rate

Air bubble-tight (Bo 1, DIN 3230)

Closing pressure

1000kPa

Size

DN25-DN100

Material

Body Cast copper or Stainless Steel ,Shaft Stainless Steel,

Actuator 

Actuator

QF/QM

Output torque

10, 16, 25, 40N.m

Power supply

AC220V or AC/DC24V

Run time

About 120S

Operating power

5VA

Output angle

90°± 3°

ON/OFF control signal

1 wire or 2 wire control

Control signal

4~20mA, 1~5V, or 0(2)~10V

Feedback signal

 DC0 -10V

Installation position

Upright to horizontalNo upset

Protection class

IP54

Ambient conditions

- 10°C. to. +55°C   0..90% RH

Weight

1kg

Material

Flame-resistant Abs

OPERATION  

The internal force sensor will turn off the actuator when the valve is locked accidentally during running, so the motor of the actuator will never overload.

  

Manual operation

The QM/QF are equipped with a manual operator knob to open or close valves in the events of power failure.

Push down the manual operator knob and turn the knob:

A: counterclockwise to drive the valve close

B: clockwise to drive the valve open

Direction of action

Repositioning the selector plug S3 can change the direction of action.

S3 ON 10V/20 mA  OFF 0V

Control signal

The control signal Vdc/mA can be changed by selector plug S1.

The control signal 0-10V/2-10V can be changed by selector plug S2

S1 ON 0-20mA/OFF 0-10V

S2 ON 2-10V/OFF 0-10V OR ON 4-20mA/OFF 0-20 mA

 

Note:

Turn the power off before changing the following setting.

DN

Dimensions(mm)

R

N

Kvs

mm

L

H

ON/OFF

MODULATING

65

93

86

120

4

90

82

80

108

95

135

8

118

105

100

120

104

150

8

125

114

DN

Dimensions(mm)   

Thread

Kvs

mm

Lmp.

L

H

R

ON/OFF

MODULATING

25

1

80

70

1

20

13

32

1-1/4

100

70

1-1/4

43

24

40

1-1/2

110

85

1-1/2

54

34

50

2

120

90

2

70

56

Valve Steam 1''-4''

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.