Welcome to ECOL - Join Free - Sign In
ups system
ups system
Supplier Info
[China Supplier]
Contact Person : Ms. He Linda
Tel : 86-755-26856844
Fax : 86-755-26811099
Product Detail
1)ups system 2)Big blue screen display. 3)Wide input range and DC start 4)19 inch line interactive UPS
Main Features
 Full digitized microprocessor controlled improves UPS reliability
 Use single chip microprocessor, PWM based for inverter output pure sine wave with synchronous phase-lock loop, LI series can make the protection of over voltage,overload over temperature speedy and accurate. High speed microprocessor control the inverter and simply the circuit, improve the agility and stability of UPS control.
 Auto-bypass
 When LI-RM/INV.fails, the inverter can transfer to Mains automatically.
 19 inch rack-mount UPS power
 19inch/3U rack-mount equipments are widely used in the internet servers, telecom field, manufacturing fields. LI-RM19inch series are in accordance with international standard for structure design.
 Communications and network management
 The availability of RS-232 communication make it possible for UPS to realize its multi-functional and multipurpose monitoring management by connecting the computers and other surveillance equipments. include:mains status,UPS working status,system setup,menu operation, remoted control and self-diagnostic,record and anylysis,system shut down etc. The network management system can also be set up by optionalSNMP slot.
 Specification
 
  
Model
Capacity VA/Watts:LI10N-INV./RM/800W, LI15N-INV./RM/1.2KW, LI20N-INV./RM/1.6KW,LI30N-INV./RM/2.4KW
Dc Input
Phase:Single phase
Voltage range:40~56 Vdc
Current:LI10N/25A, LI15N/37A, LI20N/50A, LI30N/75A
Reflected Noise:Reflected Relative Psophometrically Weighted Noise Current<2%Reflected Relative Wide Band Noise Current<10%
Inverter Output
Voltage range:220Vac±2%(DC mode)
Frequency:50/60Hz±0.1% (Auto Sensing)
Waveform:Sine wave
AC input
Voltage:165~283 Vac
Frequency:45~65Hz(Auto Sensing)(Economic mode)
Output ECO mode
Voltage:220Vac±%%(Economic mode of utility power between 165~283 Vac)
Frequency:45~65Hz(Auto Sensing)(Economic mode)
General features
Efficiency:>85%
Noise suppressor:<45dB (At 1 meter)
Working temperature:0- 40°C
Environment Humidity:< 95% non-condensing
Safety standard:IEC 62040
Software Start/ShutdownYes
Display:LED Inverter running,voltage change,battery,fault,loadLCD Input/output voltage/frequency,load battery voltage, inner temperature, and Inverter status
Alarm:Mains Failure, low battery, overload, UPS fault
Mute:Manual
Crest ratio:3:1
Protection function
Over load:>120% for 2min bypass or shutdown;>150% for 10 seconds bypass or shutdown
Short circuit:Circuit protection, no inverter output, inverter auto recovery after short circuit clearance
Low voltage on battery:Shut down
Output abnormal:Inverter auto shutdown
Communication Interface
Comconnect:True RS-232 communication port;SNMP(option)
Function:Inverter status,Battery status,Low battery,Remote shutdown,Menu operation
Physical parameter
Dimension(W×D×H mm):430X486X133/3U
Weight (Kg):LI10N-INV./RM/13,LI15N-INV./RM/15,LI20N-INV./RM/22,LI30N-INV./RM/32