Ads by Google
Key Features
1. High frequency and double conversion online UPS2. Single phase3. Fully digitized microprocessor control4. Wide input voltage range5. Advanced PFC technology6. Self-testing when UPS startup7. Advanced battery management8. Automatic battery charging in UPS off mode9. Lightning and surge protection10. Short circuit and overload protection11.Smart RS232 communication with monitoring software
C Series SERIES TECHNOLOGY SPECS
Item | Model | C1K/C1KS | C2K/C2KS | C3K/C3KS |
Capacity | VA / Watts | 1KVA / 0.7KW | 2KVA / 1.4KW | 3KVA / 2.1KW |
Input | Normal voltage | 220VAC/ 110VAC | ||
220V Voltage range | a) (118±5 ~ 300±5) VAC when Load≤50% | |||
b) (140±5 ~ 300±5) VAC when Load>50% | ||||
110V Voltage range | 80-150VAC | |||
Frequency range | 40~60Hz(adjustable) | |||
Output | Voltage range | 220/110VAC+-2% | ||
Frequency range | 50Hz/60Hz+-0.5% (Battery mode) | |||
Wave form | Pure Sine Wave | |||
Transfer between AC mode and battery mode | 0 ms | |||
Transfer between AC mode and bypass mode | Transfer time: 4ms (typical 2.5ms) | |||
Distortion (Full Load) linear load | ≤3% | ≤4% | ≤4% | |
Degree of distortion (Full Load) nonlinear load | ≤6% | ≤7% | ≤7% | |
Overload capacity | >110% 30s turn to bypass mode; >150%, 200ms turn to bypass | |||
Load peak ratio | 3:1(max) | |||
Battery For C1K/2K/3K | Type | Maintenance free valve regulated lead acid (VRLA) battery | ||
Battery voltage | 36VDC/24VDC | 96VDC/72VDC/48VDC | 96VDC/72VDC/48VDC | |
Battery number (standard type ) | 3*12V*7AH | 8*12V*7AH | 8*12V*7AH | |
Backup time (Full load) | 6Mins | 9.5Mins | 7.5Mins | |
Backup time (Half load) | 14Mins | 21Mins | 17.5Mins | |
Recharge time | 90%capacity after 8 hrs charging | |||
Long backup | C1KS/2KS/3KS | 36VDC, External | 96VDC, External | |
Display | LED | Load level / Battery level / Battery mode / Line mode / Inverter , Bypass ,Over load , Fault | ||
Audible Alarm | Battery Mode | Beeping every 4 seconds (re-settable) and every second when battery low | ||
Overload | Beeping twice every second | |||
Fault | Beeping Continuously | |||
Communications | RS-232 Interface | With monitoring software | ||
Working Environment | Surge protection | RJ-45 I/O port available for network or Fax/Modem | ||
Working temperature | - 20°C~40°C | |||
Humidity | 0-95% non-condensing | |||
Product size | WxDxH (mm) | 405*145*220 | 455*195*330 | 455*195*330 |
package dimension | WxDxH (mm) | 505*485*345 | 595*335*495 | 595*335*495 |
package weight | Kg | 30/18 | 32/15 | 35/18 |
REMARK | C*K --- Standard Type, C*KS---- Long Time Type. The 24VDC,72VDC and 48VDC are not normal model |
High Frequency Online UPS C 1KVA 2KVA 3KVA