Product Detail
Split-type CT AC Current Transducer 1.AC current input 2.Output: DC4-20mA 3.Power supply: DC24V+/-15%

YDKH Series Split Type AC Current Transducer

² Function and Features

1.No need to cut off the power or clear the cables when assemble or disassembled.

2.Transforms the measured AC current to a DC current/voltage output according to the linear scale.

3.Excellent temperature characteristic and good working stability.

4.Configuration compactness and briefness.

² Model Description

YDKH-Type-Input-Power Supply-Output

Type

30Ⅱ:(30×20mm) Split Type AC Current Transducer

80Ⅱ:(80×50mm) Split type AC Current Transducer

120Ⅱ:(120×80mm) Split type AC Current Transducer

Input (AC) 

A1: 0~50A,A2: 0~100A,A3: 0~150A,A4:0~200A,A5: 0~250A, A6: 0~300A, 

A7:0 ~500A,A8: 0~1000A

Power Supply

P1:DC24V±15%

Output (DC)

O4:4~20mA

When ordering, please check type, input range, Power supply and output range in accordance to user’s requirements.

 ² Technical Index

Standard:GB/T 13850-1998,IEC688:1992

Accuracy:0.5%

Accuracy drift:Annual Variation < 0.2%

Working frequency withstand voltage:AC2.0kV/min.1mA(between input/output/housing)

Insulation Resistance:≥20MΩ (DC500V)

Response Time:≤350ms

Input Range:AC0~1000A;,50/60Hz

Load Resistance:RL≤550Ω; 

Working Conditions:-10~50°C,10%~90%RH without condensation

Storage Conditions:-40~70°C,10%~95%RH without condensation

Installation:bent slice fix or pressing tray fix

Dimension:30Ⅱ:40mm×89mm×110mm,80Ⅱ:40mm×114mm×150mm,120Ⅱ:32.5mm×147mm×198.5mm

² Notice

1.Shielded cable and 0.5A puse wire should be connected at the power side when connecting.

2.The operating environment allows no electric dust or gases that corrodes metal or destroys insulation. The altitude is less than 2500m.

3.Don’t modify Zero and accuracy which have been calibrated by the manufacturer.

4.When close the transducer after open, make sure the split core contacts is intact, avoid any debris in the core, otherwise, it will affect the accuracy.

  

                   

Split-type CT AC Current Transducer