MBO Sereis Current Transformer for good quality
The MBO series of current transformer have beautiful outline and Convenient for mounting in many ways. The most current transform need the special mounting and the MES series used the mounting of DIN typing With a lot of times. The protective cover for the terminal block used the switching device with Safety and quick
Description
A range of (9 frames) Euro style long life design plastic case current transformer, enforced terminal makes the CT keep cooling after full load using for a long term, elegant black figure makes the CT perfectly assort with related components in high quality panel board.
Feature
-Two built in fixing methods: Side base; busbar mounting
-Built in hinged terminal cover
-Enforced terminals
-Primary current from 5A to 5000A
Specificaions
Secodary current: 5A/1A
Rated Test Voltage: 3KV AC.(1min)
Rated short-time thermal current(Ith): 60In
Rated dynamic current(Idyn): 2.5Ith
Rated Voltage(Um): 0.72KV AC
Continuous overload(Id): 1.2In
Ambient Temperature:-10oC to +50oC
Rated Frequency :50/60 Hz
Housing self-extinguishing class: VO
Safety factor: FS 5
*Other tecnical specification. on request
Standard
IEC60044-1, EN60044-1, VDE0414-44-1, GB1208-2006
Date Sheet
Type | Ration (A) | Burden (VA) | |
Class: 0.5 | Class:1.0 | ||
MBO-62/B | 5/5 | 1.5 | 2.5 |
10/5 | 1.5 | 2.5 | |
15/5 | 1.5 | 2.5 | |
20/5 | 1.5 | 2.5 | |
25/5 | 1.5 | 2.5 | |
30/5 | 1.5 | 2.5 | |
40/5 | 1.5 | 2.5 | |
50/5 | 1.5 | 2.5 | |
60/5 | 1.5 | 2.5 | |
75/5 | 1.5 | 2.5 | |
100/5 | 1.5 | 2.5 | |
150/5 | 1.5 | 2.5 | |
200/5 | 1.5 | 2.5 | |
MBO-62/20 | 30/5 | 1.5(4T) | 2.5(4T) |
40/5 | 1.5(4T) | 2.5(4T) | |
50/5 | 1.5(2T) | 2.5(2T) | |
60/5 | 1.5(2T) | 2.5(2T) | |
75/5 | 2.5(2T) | 1.5 | |
80/5 | 2.5(2T) | 1.5 | |
100/5 | 1.5 | 2.5 | |
150/5 | 2.5 | 3.75 | |
200/5 | 2.5 | 3.75 | |
MBO-62/30 | 30/5 | - | 2.5(4T) |
40/5 | - | 2.5(4T) | |
50/5 | - | 2.5(2T) | |
60/5 | - | 2.5(2T) | |
75/5 | - | 2.5(2T) | |
100/5 | 1.5 | 2.5 | |
150/5 | 1.5 | 3.75 | |
200/5 | 2.5 | 5 | |
250/5 | 2.5 | 5 | |
300/5 | 3.75 | 5 | |
MBO-62/40 | 60/5 | 1.5(3T) | 3.75(2T) |
75/5 | 1.5(2T) | 3.75(2T) | |
100/5 | 1.5 | 2.5 | |
150/5 | 1.5 | 3.75 | |
200/5 | 2.5 | 3.75 | |
250/5 | 2.5 | 3.75 | |
300/5 | 3.75 | 3.75 | |
400/5 | 3.75 | 5 | |
MBO-30 | 50/5 | - | 1.5(2T) |
60/5 | - | 1.5(2T) | |
75/5 | - | 1.5 | |
100/5 | 1.5 | 2.5 | |
150/5 | 1.5 | 2.5 | |
200/5 | 2.5 | 5 | |
250/5 | 3.75 | 5 | |
300/5 | 5 | 5 | |
400/5 | 5 | 5 | |
MBO-40 | 100/5 | 1.5 | 2.5 |
150/5 | 1.5 | 2.5 | |
200/5 | 2.5 | 5 | |
250/5 | 3.75 | 5 | |
300/5 | 5 | 5 | |
400/5 | 5 | 5 | |
500/5 | 5 | 7.5 | |
600/5 | 5 | 7.5 | |
MBO-60 | 300/5 | 1.5 | 5 |
400/5 | 2.5 | 5 | |
500/5 | 5 | 10 | |
600/5 | 5 | 10 | |
750/5 | 5 | 10 | |
800/5 | 5 | 10 | |
1000/5 | 5 | 10 | |
1200/5 | 5 | 10 | |
MBO-70 | 400/5 | 2.5 | 5 |
500/5 | 5 | 10 | |
600/5 | 5 | 10 | |
750/5 | 5 | 10 | |
800/5 | 5 | 10 | |
1000/5 | 5 | 15 | |
1200/5 | 5 | 15 | |
1500/5 | 5 | 15 | |
1600/5 | 5 | 15 | |
2000/5 | 5 | 15 | |
MBO-100 | 750/5 | 5 | 10 |
800/5 | 5 | 10 | |
1000/5 | 5 | 15 | |
1200/5 | 10 | 15 | |
1500/5 | 10 | 15 | |
1600/5 | 10 | 15 | |
2000/5 | 10 | 15 | |
2250/5 | 10 | 15 | |
2500/5 | 10 | 15 | |
3000/5 | 10 | 15 |