3-Phase Input Line Reactor compatible to ABB Inverter 1.Power Voltage:3AC380-415V 2.Phase Current:8-200A 3.Frequency:50/60Hz

3-Phase Input Line Reactor compatible to ABB Inverter

 

Welcome to Huashenglong low voltage reactor!

The line reactor is used to prevent harmonics mainly generated by power source of inverter. It helps to ensure long time running of equipment by absorbing power disturbances which may otherwise damage motors and drives. Hence, the low voltage reactor is able to increase drive reliability of equipment.

Please refer to the following data table for more details of the reactor and transformer compatible to DC speed governor and inverter of Sweden ABB Company.

P SourceMotor Power (kW)ABB Inverter3-Phase Line-in Reactor 
VoltageNormalGeneralRe-loadModelP/CurRef. No.No. 
(V)(A)ABBHSL 
 1.51.51.1ACS800-01-0003-38ACS-CHK-B3HSL119-B1021 
 2.22.21.5ACS800-01-0004-3 
 332.2ACS800-01-0005-38.510022673HSL119-B203 
 443ACS800-01-0006-311.510022681HSL119-B214 
 5.55.54ACS800-01-0009-31610022690HSL119-B226 
 7.57.55.5ACS800-01-0011-318.510015197HSL119-B236 
3AC11117.5ACS800-01-0016-32710015201HSL119-B247 
380151511ACS800-01-0020-33410015227HSL119-B256 
4002218.515ACS800-01-0025-34210027233HSL119-B266 
415302218.5ACS800-01-0030-35010015243HSL119-B277 
 373022ACS800-01-0040-36810015251HSL119-B288

Feature

1. The line reactor greatly reduces catastrophic drive failures due to transient over-voltage.

2. The low voltage reactor decreases nuisance over-voltage trips due to line transients, drastically:

(1)Utility power factor correction

(2)Switching large AC motor loads

(3)Switching large transformers

(4)High AC line conditions

3. Line-side fuse operation during unsymmetrical voltage sags is reduced to the minimum:

(1)Utility system line-to-ground faults

(2)Unbalanced phase currents

4. The line reactor can also prevent harmonics and effectively improve power factor.

  

Service Conditions:

   1. Service Site: Indoor or Outdoor

   2. Ambient Temp.:-40~40 Degree (Or According To Customer's Requirement)

   3. Altitude: <=10000m (If It Exceeding To 1000m, Pleas Declare In Order).

   4. Max. Wind Speed: 35m/S

   5. Relative Humidity: <=90%

   6. Earthquake Resistant Capability: Horizontal Direction 0.3g Verticle Direction0.15g (Or By Customer's Requirements) 

Packing

Protected by water-repellent cloth, secured and packed in wooden case

Delivery Time

10-30 days depending on quantity ordered