Ads by Google
Transmitter:
Output:Direct connection outputClamp coupling outputRadiation outputOutput frequency:Pipe tracing frequency: 500Hz, 1kHz, 8kHz, 33kHz, 66kHz, and 93kHz. Here 500Hz and 1kHz are complex frequency.Fault locating:8Hz very low complex frequency.
Output power:For 500Hz, 1kHz, 8kHz, 33kHz, and fault locating frequency, the power consumption is max. 10W, four steps adjustable (2.5W, 5 W, 7.5 W and 10 W).For 66kHz and 93kHz, the power consumption is 1W.Output voltage:Max. 200V, it can be adjusted according to the load.
Impedance matching:Fully automatic.
Overload and short protection:Fully automatic.
HMI:128×64 dots LCD.
Internal battery:Lithium cell battery, 14.8V,7Ah.
External power supply:Rated voltage 12VDCCigar lighter of car outputCharger:Input: AC100~240V, 50/60Hz;
Output: DC16.8V, 2A.
Working condition:Temperature: -10°C-+40°CHumidity: 5-90%RHAltitude: <4500mDimension(mm):275×220×100 for the main unit.
Weight:2.4kg for the main unit.
Receiver:
Signal input:Internal receiving loopClamp1kHz Mini Sensor8kHz Mini SensorA Frame supportReceiving frequency:Active detection frequency for Pipes:500Hz, 1kHz, 8kHz, 33kHz, 66kHz, and 93kHz.
Passive detection frequency for Pipes:Power frequency
Radio frequency (RF).
Clamp identification frequency:500Hz complex frequency.
Clamp current measurement frequency:500Hz, 1kHz, 8kHz
Mini sensor identification frequency:1kHz, 8kHz
Grounding fault locating frequency:8Hz complex frequency
Pipe detection mode:Intelligent Peak Method (Wide): Suitable for active detection.Peak Method:Suitable for passive detection.
Narrow Method.Null Method.Cable Identification mode:Clamp intelligent identification.Clamp current measurement.Mini sensor identification.Human-machine Interface:320×240 LCD
Internal battery:Lithium cell battery, 7.4V, 7Ah.
Charger:Input: AC100~240V, 50/60Hz
Output: DC 8.4V, 2A/3A.
Dimensions (w x h x d):700mm×270mm×120mm (main unit)
Weight:3.5kg (main unit)
Working condition:Temperature: -10°C-+40°CHumidity: 5-90%RHAltitude: <4500m