Single Output Switching Power Supply
Single Output S-100 Series Feature: High efficiency, high reliability, lost costUniversal AC input range selected by switch100% full load burn-in testLED indicator for power onProtections: Short circuit/Over loadCooling by free air conventionFixed switching frequency at 25 KHz1 year warranty | |||||||
Model | S-100-5 | S-100-12 | S-100-15 | S-100-24 | |||
Output | DC Voltage | 5V | 12V | 15V | 24V | ||
Voltage Tolerance | ±2% | ±1% | ±1% | ±1% | |||
Rated Current | 20A | 8.5A | 6.7A | 4.5A | |||
Current Range | 0-20A | 0-8.5A | 0-6.7A | 0-4.5A | |||
Rated Power | 100W | 102W | 100.5W | 108W | |||
Ripple & Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |||
DC Adjustment Range | -5%,+10% | ±10% | ±10% | ±10% | |||
Setup, Rise, Hold Time | 200ms,80ms,20ms at full load | ||||||
Input | Voltage Range | 85-132VAC/170-264VAC 47-63Hz; Selected by switch 255-370VDC | |||||
AC Current | 2.4A/115V 1.2A/230V | ||||||
Efficiency | 78% | 81% | 81% | 84% | |||
Inrush Current | Cold start 30A/115VAC 60A/230VAC | ||||||
Leakage Current | less than 1mA/240VAC | ||||||
Protection | Over Load | 115%-165% | |||||
Protection type: Fold back current limiting, recovers automatically after fault condition is removed | |||||||
Environment | Working Temp., Humidity | -10 °C- +60 °C; 20%-90% RH | |||||
Storage Temp., Humidity | -20 °C- +85 °C;10%-95 %RH | ||||||
Vibration | 10-500Hz,2G 10min./1cycle, period for 60 min, each along X, Y, Z axes | ||||||
Safety | Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | ||||||
Standard | Safety Standard | Design refer to UL1012 | |||||
EMC Standard | Design refer to FFC Part15 J Conduction Class B | ||||||
Others | Weight | 0.62Kg | |||||
Dimensions | 199*98*38mm(L*W*H) |