60W 24V 2.5A single output power supply/cctv power supply/dc power supply S-60 CE certification, better Thermal Dissipation 60W 24V 2.5A single output power supply/cctv power supply/dc power supply S-60

1. 105oC Output capacitor

2. AC input power suitable for the world

3. High efficiency and low operation temperature

4. Soft-start current can reduce the AC input impact effeciticly

5. With short-circui and overload protection

6. Compact size, ligh weight

7. 100% full-load burn-in test

8. Installed with EMI filter, minimum wave

Model

S-60-5

S-60-12

S-60-15

S-60-24

DC output voltage

5V

12V

15V

24V

Output voltage rang(Note:2)

±2%

±1%

±1%

±1%

Rated output current

12A

5A

4A

2.5A

Output current range

0-12A

0-5A

0-4A

0-2.5A

Wave and noise(Note:3)

120mVp-p

120mVp-p

150mVp-p

150mVp-p

Inlet stability(Note:4)

±0.5%

±0.5%

±0.5%

±0.5%

Load stability(Note:5)

±1%

±0.5%

±0.5%

±0.5%

DC output power

60W

60W

60W

40W

Efficiency

72%

76%

77%

79%

Adjustale range for DC voltage

 +10,-5%

+10%

+10%

+10%

Input current1.6A/115V 0.8A/230V
AC Inrush currentCold-start current 30A/115V 60A/230V
Leakage current<3.5mA/240VAC
Overload protection105%~150% Type: pulsing hiccup shutdown Reset: auto recovery
Temperature coefficient±0.03%/°c(0~50°c)
Setup, rise, hold up time800ms, 50ms, 10ms/115V 300ms, 50ms, 80ms/230VAC
Vibration10-500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal 1.5KVAC, Input and enclosuer 1.5 KVAC, Output and enclosuer 0.5 KVAC
Working temperature and humidity -10°c~+60°c Refer to output derating curve, 20%~90% RH
Store temperature and humidity -20°c~+85°c, 10%~95%RH
Weight0.5Kgs 
Satety standardsUL 1012 TUV EN6050(IEC, UL 1950) Approved
EMC standardsCISPR22(EN55022), IEC801-2,3,4 IEC555-2 Verfication

Note:                                                                                                                                                                1. The testing condition for the parameter above is: 230VAC input, rated load, 25°c 70% RH.Temperatuer.                     

2. Error: include the setting error, line stability and load stability.(Note:5).                                                             

3.Wave test: adopting "A12" double wire for 20 MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting.                                                                                                                                                      4. Inlet voltage stability test: wht is overload, the lowest voltage of inlet is up to the highest voltage.                         

5. Load stability test: The load is from 0% to 100%

Anything you concern, please be free to contact us. We will be more than happy to offer any help we can.