Welcome to ECOL - Join Free - Sign In
200W 5V Switching power supply S-200-5
200W 5V Switching power supply S-200-5
Supplier Info
[China Supplier]
Contact Person : Mr. Eric
Tel : 86-577-61750378
Fax : 86-577-61750377
Product Detail
S-200 MEAN WELL AC DC S-200 High quality/S-200 UL CE EMC S-200 1years warranty S-200

Switching power supply S-200-5 

ModelS-200-5S-200-12S-200-15S-200-24
DC output voltage5V12V15V24V
Output voltage rang(Note:2)±2%±1%±1%±1%
Rated output current35A16.5A13.3A8.5A
Output current range0-35A0-16.5A0-13.3A0-8.5A
Wave and noise(Note:3)100mVp-p100mVp-p100mVp-p100mVp-p
Inlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%
Load stability(Note:5)±1%±0.5%±0.5%±0.5%
DC output power200W200W200W200W
Efficiency75%80%80%82%
Adjustale range for DC voltage4.75-5.5V10.8-13.2V13.5-16.5V21.6-26.4V
AC input voltage range170~264VAC 47~63Hz 248~370VDC
Input current4.2A/115V 2.2A/230V
AC Inrush currentCold-start current 18A/115V 36A/230V
Leakage current<0.5mA/240VAC
Overload protection105%~150% Type: pulsing hiccup shutdown Reset: auto recovery
Over-voltage protection115%~135%
Temperature coefficient±0.03%/°c(0~50°c)
Setup, rise, hold up time200ms, 100ms, 20ms
Vibration10-500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal 1.5KVAC, Input and enclosuer 1.5 KVAC, Output and enclosuer 0.5 KVAC
Working temperature and humidity -10°c~+60°c, Refer to output derating curve, 20%~90% RH
Store temperature and humidity -20°c~+85°c, 10%~95%RH
Weight0.9Kgs
Satety standardsMeet UL 1012 requirment ( Not apply for the mark)
EMC standardsMeet FCC PART 15 J Conduction calss A

Note:                                                                                                                                                                  1. The testing condition for the parameter above is: 230VAC input, rated load, 25°c 70% RH.Temperatuer.                     

2. Error: include the setting error, line stability and load stability.(Note:5).                                                             

3.Wave test: adopting "A12" double wire for 20 MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting.                                                                                                                                                      4. Inlet voltage stability test: wht is overload, the lowest voltage of inlet is up to the highest voltage.                           

5. Load stability test: The load is from 0% to 100%

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.