Solar controller for pressure solar water heater system,intelligent control the circulation pump,Anti-dry protection

1 collector array – 1 storage tank – 1 pump and auxiliary heating Description: The solar circuit pump (R1) is switched on as soon as the switch-on temperature difference (Delta Ton) between the collector array (T1) and the storage tank (T2) is reached. If the temperature difference between the collector array (T1) and storage tank (T2) drops below the switch-off temperature difference (Delta Toff), or the temperature of storage tank (T3) reaches the preset maximum storage temperature, then the solar circuit pump ( R1) is switched off. Back-up heating by auxiliary boiler (detailed see paragraph 4.3): Within the preset time section of back-up heating, if the temperature T3 is below the switch-on temperature, then the circulation pump ( H1) of back-up heating is triggered, when T3 is heated to the switch-off temperature, circulation pump H1 of back-up heating is ceased.

 Main technical data of Solar controller for  pressure solar water heater system:

1.Main  menu  DT  O  &  DT  F  Temperature  difference  function2.Main  menu-THET  timing  heating3.TEMP  Temperature  main  menu4.EM  Emergency  collector  temperature(emergency  switch-off  temperature  of  collector)5.CMX  Maximum  limited  collector  temperature  (collector  cooling  function)6.CMN  low  temperature  protection  of  collector7.CFR  frost  protection  of  collector8.SMX  Maximum  temperature  of  tank9.REC  Tank  re-cooling  function10.Celsius  and  Fahrenheit  temperature  transferring11.FUN  Auxiliary  function12.DVWG  Anti-Legionella  function13.CIRC  Temperature  controlled  hot  water  circulation  pump14.nMIN  Solar  circulation  pump  speed  adjusting  (RPM  speed  controlling)(Only  available  on  SR530C8Q)15.OHQM  Thermal  energy  measuring  (Only  available  on  SR530C8Q)16.INTV  Pump  interval  function      (Only  available  on  SR530C8Q)17.BYPR  High  temperature  by-pass  function(tank  temperature  automatically  adjusting)18.  HND  Manual  mode19.PASS  Password  setting20.LOAD  Recovery  to  factory  setting21.ON/OFF  button22.Holiday  function23.Manual  heating24.Temperature  query  function25.Memory  Protection26.Anti-dry  heating  Protection27.Screen  protection

Solar controller for pressure solar water heater system

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.