STA Load cell
Type | STA | |
Accuracy class according to OIML R60Maximal numbers of load cell verification intervals (nLC) | -3000 | |
Maximal capacity (Emax) Weight (G), approx. Minimum load cell verification interval (Vmin)Sensitivity (Cn)Zero balanceTemperature effect on sensitivity (TKc) *Temperature effect on zero balance (TKo)Non-linearity (dlin) *Repeatability (drep) *Hysteresis error (dhy) *Creep (dDR)in 30 min. Input resistance (RLC)Red(+)-white(-)Output resistance (Ro) blue(+)-green(-)Reference excitation voltage UrefMaximal excitation voltageInsulation resistance RisNominal temperature rangeService temperature rangeStorage temperature range | kgkg% of CnmV/VmV/V% of Cn/k% of Cn/k%%%%ΩΩV(DC/AC)V(DC/AC)GΩoFoFoF | 1;2;3;5;10;20;300.80.032±0.25%0±2%< ±0.0012<±0.0040<±0.017<±0.017<±0.017< ±0.023400 ±25350±30.51218>250 VDC -10+4015+105-30+5015+125-50+85-15+160 |
Safe load limit (EL) Breaking load (Ed) | % of Cn% of Cn | 150300 |
Protection class (IP) acc. to IEC529 | IP65 | |
Material | Steel alloy | |
Optionally | Explosion proof version (Ex ib II CT4) |
The data for deviation of linearity, repeatability, hysteresis error and temperature effect on sensitivity are typical values. The sum of these data meets the requirements according to OIML R60.
High accuracy up to 3 000d for scales class IIISuitable for use under conditions of tension and compression Protection to IP66Overload stop both for tension & compressionExplosion proof version(Ex ib II CT4) Available Options :- Service temperature range up to 120 [248oF] - Service lightning proof- 6-wire circuitMax. Capacities:1kg-30kg