Welcome to ECOL - Join Free - Sign In
Cryo Lipolaser Body Shape System/coolsculpting
Cryo Lipolaser Body Shape System/coolsculpting
Supplier Info
[China Supplier]
Contact Person : Ms. Lee Edith
Tel : 0086-20-28659298
Fax : 0086-20-28659319
Product Detail
Cryo Lipolaser Body Shape System/Body slimming equipment

Cryo Lipolaser Body Shape System

Cryo Theory

Coolsculpting cool shape machine is a new, non-invasive way to gently and effectively reduce fat in targeted areas of the body that results in a noticeable, natural-looking fat reduction in the treated areas. Triglyceride in fats will be converted into solid in particular low temperatures. What makes the Coolsculpting cool shape machine procedure different is that it uses advanced cooling technology to selectively target fat bulges and eliminate fat cells through a gradual process that does not harm the surrounding tissues. This procedure can reduce unwanted abdominal fat, love handles (flanks), and back fat.

 

When fat cells are exposed to precise cooling, they trigger a process of natural removal that gradually reduces the thickness of the fat layer. And the fat cells in the treated area are gently eliminated through the body’s normal metabolism process, to eliminate unwanted fat.

 

 Through the freezing effect, remove the fat cell triglyceride off heat, and will remain at 4 °C, so the cold coagulation, and therefore premature aging and death. Fat cells in the cold, it will start clearing the natural decomposition process, so that gradually thinner fat layer. Through the normal metabolic processes, decreasing the fat layer, to achieve the purpose of partial melting fat.

 

Fat cells can be significantly reduced, the fat layer also will become thinner, so that the fat blocks will be killed one by

one.Cooling Skin protection while lifting and tightening.The contact cooling of the handle piece surface regulates the

temperature of the skin and protects fine dermal structures, realizing the fast body-reshape effects while tightening

skin!

 

Theory of Lipolaser

The main role of the low-energy laser bio-stimulation (Bio stimulation), that is, through the give appropriate energy to stimulate the biological cells and induce or strengthen a number of physiological responses, including to promote local blood circulation, regulate cell function, enhance immune function, promote cell metabolism and proliferation.

 

Wavelength of 650nm-660nm red laser just in human eye color of the visible spectrum, so we can see the red light 650nm -660nm  can penetrate the organization up to 8-10mm, the effective activation and repair cells, stimulate the synthesis of cell metabolism, for the superficial cells biochemical stimulation and hyperemia. Irradiation meridian points to stimulate the meridian points related organizations, the skin tissue will not cause harm to exempt patients fear of needles, and also have the function to stimulate the meridians in a healthy way.

 

When required, signals from the brain result in the contents of cells being released and the contents are then

metabolized to provide energy to the bodies tissues.In essence the adipose cells are acting as rechargeable batteries, sometimes being charged up and sometimes being used depleted depending on a persons diet and exercise. When we exercise we create a demand for extra energy in the bodies tissues and normally the body responds by releasing the fuel stored in any adipose tissue. I-lipo simply stimulates the release of these contents before the body has acctually embarked on the exercise,which enables us to specifically concentrate on troublesome areas.The treatment is relaxing and pain free and a typical client can expect to reduce an area by 1-2 dress sizes during a course of treatments.While a quick fix can be obtained in just a few sessions, adjustments to diet and exercise regime will ensure a long term result.

Skin Antifreeze

Qualified antifreeze should be used during the treatment, to avoid frostbite when temperature lowers to the 0 to -20 degree. Consumables, purchase on your own.

Technical Note

Hardware structure of the machine parts, injection molded parts, and the majority of electronic components,connectors meet the requirements of the EU ,Only a few parts as the global technology limitations that may affect product reliability and not find a substitute for the toxic and hazardous substances, please be assured to use, use under normal conditions will not cause health effects on users.

Maintenance Instruction

 

1. Medical equipment or appliances close to the device may be resulting in operational failure due to interference,

2. The machine is a precise apparatus; do not use it at place with high temperature, humidity, dusty, smokes, and vapor.

3. If there comes a failure, please shut down the power immediately, and send it to the distributor or manufacturer for maintenance. Do not repair on your own.

4. The cooling fluid is pure water; keep it clean during transportation or long time no use. And should can properly before use.

5. Exclusion of liability

(1)If fire, earthquake, war occurred.

(2)The fault of the user, operator error;

(3)Damage caused by using other method (not included in the use manual).

(4)Operate without the manual's guide.

6.After using the machine for over 40 hours , please take off the dust filter{7} and clean it

7. Do not make the machine close to the wall , keeping a 30cm space around for cooling .

8. The servive life of the cooling dissolving fat handle is about 5000 hours .

Before and After

Parameter

1.Machine Measure:65CMX52CMX40CMCM

2.Outside Package:79CMX63CMX45CM

3.LED Light wave length: 492-455nm; Laser Wave length :650nm-660nm

4.Voltage:220V/50Hz or 110V/50Hz or 110V/60Hz;

5.Touch Screen:8 inch touch screen;

6. Power Consumption: ≤400W;

7. Cooling device output temperature: 5 degree~-10°C degree

8. Cooling device output pressure: 0-100Kpa

9. Cooling liquid: pure water, with 4.5L

10. Default working time: 0-60 minutes

11. Fuse size: F3AL250V

12. Gross Weight: 42KGS

13. Relative Humidity: 85%

14. Atmospheric pressure:88KPa ~110KPa

15. Laser Energy Output: 32*80MW

16. Handle pieces: One Coolsculpting Handle Piece, 4 pcs laser pads, 8pcs laser Lamp for each pads;

17. Laser Classification: Electrical Class 1, Type B applied part;

18. Mode of Operation: Continuous

19. Environmental: 10C to 30C /50F to 86F Non-condensing;

20. Requirement: Humidities Below75%RH

21. Safety: In Board Diagnostics