TPOW horizontal single-stage double-suction volute split casing pump
Range of Application:Pressurized water transportation in waterworks, cycling use of water in air-conditioning, fire system, industrial water supply system, shipbuilding and oil refining.
Outlet diameter of pump: DN 80-800mm..Capacity: Q≤11600m3/hHead: H≤200mWorking pressure: P≤2.5PaWorking temperature: T≤105Working voltageU=380V/6kV/1 0k
Type Designation
TPOW 300-450 (I) A
TPOW:Volute double-suction centrifugal pump
300:Diameter of pump outlet (mm)
450:Nominal diameter of impeller (mm)
(I): Flow classification
A : Primary cutting of impeller
Note :The following performance parameter is just for reference !
Type | Capacity | Head | Speed | Power | Efficiency | NPSH | Impeller diameter | Net Weight | ||
m3/h | l/s | m | rpm | kw | (%) | m | mm | KG | ||
TPOW80-280 | 60.0 172.0 220.5 | 16.7 47.8 61.2 | 102.0 82.5 66.0 | 2950 | 75 | 77 | 6.8 | 225 | 194 | |
A | 58.0 160.0 203.0 | 16.1 44.4 56.3 | 88.0 71.5 57.0 | 55 | 76.2 | 255 | ||||
B | 57.0 146.7 188.5 | 15.8 40.8 52.3 | 74.0 60.0 49.0 | 45 | 75.2 | 235 | ||||
C | 56.0 132.6 170.0 | 15.5 36.8 47.2 | 61.0 49.0 40.0 | 30 | 74.4 | 215 |
HORIZONTAL SINGLE STAGE DOUBLE SUCTION SPLIT CASING PUMP