66kv current transformer transformer 1,outdoor single phase 2, ISO9001:2008 3,organic insulation dry-type Outdoor organic insulation current transformer 66kv Feature1,It is organic ... amount and stable. Small dielectric is loss2, The current ratio can be changed easily by change the ... voltage for equipment72.5kvRated frequency50 or 60 HzRated current ratio2×50-2×1000/5or 1ANumber of secondary ...
... price, Japan quality! 100% fully copper.DescriptionThe type current transformer is a kind of steel tank oil-immersed type of ... C ~+40°C. LJW1-35 oil type 35kv outdoor current transformer oil immersed 35kv outdoor current transformerTechnical data1. Rated insulation level: 40.5/95 ... ~(50)83Overall Dimension LJW1-35 oil type 35kv outdoor current transformer oil immersed 35kv outdoor current transformer
Current Transformer LB5-66 LB6-110, LB5-66, LVB(T)-35. Highest voltage(kv) : 66 Highest system voltage(kv) : 72.5 Current Transformer LB5-66ELECTRICAL CHARACTERISTICSHighest voltage(KV ... from high boltage cable paper. It will be inmersed with transformer oil after desiccationg under vaccum. It has advantages of stable ...
RATED VOLTAGE:0.66kV , RATED CURRENT:5A-5000A ; CLASS:0.2/.0.5 TypeRated current (A)Rated power (VA)Weight (kg)Class:0.5Class ... ,40,40,4WINDOWS TYPEBar: 40 X 10mm.conductor: Ø30mm.TypeRated current (A)Rated power (VA)Weight (kg)Class:0.5Class:1MSQ ... : 80 X 30mm.or 100 X 10mm.conductor:Ø60mm.TypeRated current (A)Rated power (VA)Weight (kg)Class:0.5Class:1MSQ ...
... /EN60044-1 3.Degree of protection:IP 20 4.Secondary current :5A Current transformer (CT) is used for measuring electric energy and ... current, relay protection in the electric system.Features: 1) Type 1 ( ... at larger secondary impedance and act as the zero-sequence current transformer BH-0.66 series Current Transformer (CT)
... Outdoor split core current transformer Rated primary current: 1~220A max Accuracy: 1% Good linearity RoHS compliant ECS24 outdoor split core current transformer series is outdoor current transformer, split core current transformer ... ct) Accuracy : 1% Phase error at rated current range: ≤1° Operating Temperature Range: -40~ ... : DC500V/100MΩ min Outdoor split core current transformer (1~220A max)
... , for indoor, current transformers, low voltage switchgear, outdoor current transformer, box-type substation current transformers and other various current transformer the place. TheBWCT-NZ current transformer secondary overvoltage protection ...
... , and easy to install. BH-0.66KV Current Transformer BH-0.66kv Current Transformer is used for metering current and electric energy, protection in the electrical ... 60HZ and rated voltage under 0.66KV. Technical Data:Primary Rated Current(A)Secondary Rated Current(A)Primary cable winding turnsAccuracy ClassSecondary ... .50.20.5S0.2S5400~5005600~200010Contour Dimensions: BH-0.66KV Current Transformer
... voltage current transformer *for electric equipment protection, and to test, control, display *good quality, OEM DELIXI LMZ1 series low voltage current transformerApplication:1 ... to the rated frequency 50-60Hz and rated voltage 0.66KV.2.The iron core is loop type, the secondary windings ... for fixing copper bar-3 pieces.Specification: DELIXI BH-0.66 series indoor low voltage current transformer
... 66) series sleeve type current transformer, including TPS, TPY level transient protection sleevetype current transformer .Product: Class PR current transformer(SF6 product use) Epoxy Resin Casting Casing Current Transformer ... Rectification Current Transformer TPY transient protective current 500KV/GIS use CT With rising seat CT 35kv/10kv Outdoor pouring transformer You ...
... , Outdoor type 3. Stable performance. High voltage tested 4. humidity 70%. 5.secondary load (va) cos=0. Detailed Product Description1. Current transformer is ... a very useful device because it converts high ACcurrent to small easily manageable value.Current transformers consist of ... .01.01.0Rated burden11.52.52.52.5 multi-mount current transformer
current transformer testing equipment AC circuit current transformer testing equipment Rated voltage: below 0.66kV CE CCC current transformer testing equipment LZX-10QDetailed Product DescriptionIntensive insulation type Rated ...
1)CE certified 2)Outdoor type 3)ISO 9001 factory 4)Quality guarantee 5)Oil ... combinationAccuracy class and rated output COSØ=0.81s thermal current(KA)Rated dynamic current(KA)0.2S0.20.510p10LJW-10 LJWD-10 ... : any special requirements can be negotiate with us. LJW-10 current transformer (same LB-10)
1. Name: current transformer 2. Model: MSQ 3. Class: 0.5, 1.0 MSQ current transformerApplicaton The MSQ series current transformers can be sued to ... set of mine transformer.FeaturesPrimary current: 5A-150A Secondary current: 5A, 1A Standard approval: VDE0414, BS7626, IEC185 Maximum voltage: 0.66kv Frequency: 50-60KV ...
MSQ,BH-0.66,LM,LMK1,LMKJ1,LMZ1,LMZJ1 Series Current Transformer This series of CT can be applied to test, control, ... be also applied to form a complete set of mine transformer Current Transformer
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.