... outdoor h.v.Current-limiting fuse is used for protecting for voltage transformer,protecting from overload,fuse RW10-35 type outdoor h ... .v.Current-limiting fuse is used for protecting for voltage ... of rated current,it melts in 1 hour.(high voltage fuse,cut out fuse,fuse)
... with porcelain or silicon rubber insulators. Fuse Cut out, Drop out Fuse:HS Code: 85351000 Trademark: RIGHT Standard: IEEEC37.41Packing:CARTONTypeRated volt- ... CMRTF-15331008,0001707082027.568×17×15RTF-15 3320010.0001707082027.5 Fuse Cut out, Drop out Fuse
... voltage:10kv max.operating voltage:12kv drop-out fuse techinical parameters:rated voltage:10kvmax.operating voltage:12kvrated current:100A ... max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:> 2.6Cm/kv 1 ... /1001011.51005.81730752.5PRW7-10/1001011.51005.81730752.5 Drop Out Fuse/ Cut Out Fuse
Supply 10kv-36kv Drop-out Fuse Porcelain Inuslator in Gray, Brown ,White glaze,according to IEC standard . Supply 10kv-36kv Drop-out Fuse Porcelain Inuslator in Gray, Brown ,White glaze,according to IEC standard . Drop out fuse cut out porcelain insulator
1)Type :Cut Out Fuse 500V, 400A 2)Colour :Gray LV pole mounted fuse out / fuse holder/ fuse carrier1) Current rating:10A,15A,25A,30A,40A,50A,63A,80A,100A,200A,250A,315A,400A2)MAX rated Voltage:500V3)Breaking current:46KA LV pole mounted fuse cut out
... with composite-polymer silicon insulators Drop-out fuse product introductionDrop-out fuse cutout and load switching fuse cutout are of outdoor used high ... on/off loading current. Drop-out fuse cutout is composed of insulating insulator supports and fuse tube.staatic contacts is fixed on ... two ends of fuse tube. Fuse tube is composed of inside arc-extinguishing tube, ...
1.certification:ISO9001 2.material:brass 3.produce according to the client's requirements 4.OEM orders are welcome Cutout fuse brass casting partsmaterial: brassfinish: sanding polish, Tin plating, silver platingproduce as your special needs
... electrical cperformances 3.Strong breaking currecting when faulty High voltage fuse cutoutRated voltage(kV)Rated current (A)BreakingCurrent (A)Impulsevoltage(BIL ...
reliable quality ,competive price,fast delivery ,good sevice. The technical specification: 1. The density≥1.80g/cm3 2. Water absorption rate≤0.15% 3. Bending strength≥400Mpa 4. Compression strength≥98Mpa 5. Withstand voltage along laminas at normal condition 5 min ≥25KV 6. Withstand voltage across laminas at transformer oil 90±2oC 5min ≥12MV/m Note: The diameter according to customer's order.
Fuse Cut-Outs Standards: IEC 600282-2 Fuse Cut-OutsApplication: protection device for protecting power system from over-load ... .Technical Data:Rated voltage: 36kV.Rated current: up to 200A. Fuse Cut-Outs
... 4.Easy installation 5.Strong breaking current capacity Electric fuse cut out / 12KV Out-door drop out / new type high quality / 2012 new style ... DescriptionThe YDNCX fuse cutout has a long history of providing ... or fault conditions.RatingThe YDNCX accommodate a 100A fuse-holder, a 200A fuse-holder.Designing feature1).The 100A fuseholder can ...
... Drop out fuse cut out and and load switching fuse cutout are of outdoor used high voltage protective device. Drop out fuse cut out and and load switching fuse ... overhead, and on/off loading current. Cut out fuse is composed of insulate insulators and fuse tube, static contacts is fixed on ... 250 - 720mm Standard: ANSI We can supplied the others Fuse links, Fuse holders, Fuse bases etc. Cut Out Fuse
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.