Welcome to ECOL - Join Free - Sign In
40 - 58 Results for

contactor overload

Found 53023 Products
Thermal Overload Relay (LR2-D)
... motor is overload. The relay has different mechanism and temperature compensation & can be pluged in LC1-D series AC contactor. It is ... the most advanced thermal relay in the nineties in the world. Thermal Overload Relay (LR2-D ...
Supplier: Yueqing Zhicheng Electrical Equipment Co., Ltd. [China Manufacturers]

CF3F AC Contactor

Mar 05, 2012
CF3F AC Contactor
... .5CF3F49100858045752136CF3F501601109555902746.9CF3F51160140120751103560CF3F52200170160901503866CF3F532102051651101605086CF3F5430025023013222058100CF3F5530030026016025066114CF3F5640040038020035581140CF3F68630630600335560160278Application CF3F AC contactor is suitable in electrical system ... overload or phase-failure. They are made according to IEC947, BS5424&VDE 0660. The contactor ...
Supplier: Shanghai FATO Group Co., Ltd. [China Manufacturers]
3TB SERIES AC CONTACTOR 380V:9~32A 660V:7.2~18A
... 3).High cost performance 3TB SERIES AC CONTACTORAPPLICATION3TF series AC contactor are suitable in electrical system with AC 50/60Hz, rated ... with suitable thermal overload orphase-failure. They are made according to IEC 60947, BS 5424 & VDE 0660.The contactor is a straight ... . All series products can be mounted by screw, Ie≤32A contactor also byinstallation rail.TypeCJX(3TB40)CJX(3TB41)CJX(3TB42)CJX ...
Supplier: Yueqing Geenwich Imp & Exp Co., Ltd. [China Manufacturers]
LC1-D32 new type AC contactor
... quality,and low pr LC1-D32 new type ac contactor electrical contactorLC1-D(New type) AC Contactors AC Contactors ... in AC-3220/240V15KW18.5KW22KW25KW30KW40KW380/400V22KW30KW37KW45KW55KW75KW415/440V25/30KW37KW45KW45KW59KW80KW500V30KW37KW55KW55KW75KW90KW660/690V33KW37KW45KW45KW80KW100KW1000V30KW37KW45KW45KW75KW90KWThermal overload relaysclass 10A17...50A17...70A17...80A17...104A60...150A60...150Aclass ...
Supplier: Yueqing Kangling Electric Appliance Factory [China Manufacturers]

LC1-F AC CONTACTOR

Dec 03, 2012
LC1-F AC CONTACTOR
LC1-F AC CONTACTOR: 1.Certificates: CE, PCT 2. Electric ratings: AC50/60Hz, up ... 800A 3.Standard: IEC/EN 60947-4 LC1-F AC CONTACTOR General 1.1 Certificates: CE, PCT1.2 Electric ratings: AC50 ... 800A;1.3 Application: remote making & breaking circuits; protectcircuit from overload when assembling with thermalover-load relay;1.4 Ambient temperature ... .8 Standard: IEC/EN 60947-4-1 LC1-F AC CONTACTOR
Supplier: Wenzhou Solak Import & Export Co., Ltd. [China Manufacturers]

AC Contactor

Mar 13, 2013
AC Contactor
... up to 95A.The contactor can switch on or off long distance channel. With the suitable overload thermal relay together, ... the contactor can compose the electromagnetic starter to protect ... the channel which may be overload the contactor is suitable for frequently starting and controlling the ...
Supplier: Zhejiang YUYE Electric Co., Ltd. [China Manufacturers]
protection motor JR20 series thermal relay 63L adjustable thermal overload relay
... three-phase motor against overload and phase losing,and forming electrom-agnetic with starter CJ20 series AC contactor. It has functions of ...
Supplier: Yueqing Guoke Electric Co., Ltd. [China Manufacturers]
SB1 ( DZ47 ) 2p ac 3ka breaking capacity circuit breaker with short circuit and overload protection
... .short circuit and overload protection 1.About us We're specialized in designing and manufacturing circuit breaker and contactor in China with ... 1A up to 63A for protecting cables and equipment against overload and short circuit.and also for isolation. 2).The product ... ac 3ka breaking capacity circuit breaker with short circuit and overload protection
Supplier: Wenzhou Ausin Electric Co., Ltd. [China Manufacturers]
SG-3TF AC CONTACTOR AC
... system. They can form electromagnetic starters with suitable thermal overload relays 3UA series to protect system and motors against ... overload or phase-failure. They are made according to IEC947-2, BS5424 & VDE0660. The contactor is a straight ... All series products can be mounted by screws, le≤32A contactor also by installation rail. SPECIFICATION TypeRated thermal current(A)Rated ...
Supplier: Jiangxi Shuanghong Technology Electric Co., Ltd. [China Manufacturers]
ABB Magnetic AC Contactor
... are made by ABB company. 1. ApplicationABB magnetic ac contactor are originated from ABB company, now we develop it ... delay & mechanical interlocking devices etc, it becomes delaying contactor, mechanical interlocking contactor, star-delta starter.2. Technical DataTable 1 TypeA9A12A16A26A30A40A50A63Rated Current ... IP20Power Rating AC-3, 400V, kW3745557590110140160 ABB Magnetic AC Contactor
Supplier: Zhejiang Minyang Electric Co., Ltd. [China Manufacturers]
3TF32-33 ac contactor
... &reliable quality 4)3C &CE ac contactor 5)Made in Chi Application: ZS3TF series AC contactor are suitable for electrical system with ... be organized into thermal magnetic starter and applied to thermal overload relay. 3TF series are used to protect system and motors ... from overload or phase failure. They are made according to IEC947, BS5424 ...
Supplier: Yueqing Zhongshuo Electric Co., Ltd. [China Manufacturers]
3UA ,thermal overload relay
3UA Thermal overload relay 1. High quality & good Price 2. Standard: IEC60947 3UA ... is overload. The relay has different mechanism and temperature compensation& can be plunged in 3TB 3TF series AC contactor. 3UA ,thermal overload relay ...
Supplier: Wenzhou Thinke Electric Co., Ltd. [China Manufacturers]
LR2 Thermal overload relay
... of exploitaton FunctionsSwitching off afternating current consumers at current overload making of control systems for consumersused as a ... cable teminal for joining to the consumer to the contactor through the relay terminals the connecting terminals with the ... before the combination contactor-thermal relay,a suitably measured breaker or safety device should be mounted... LR2 Thermal overload relay
Supplier: Dalian Gui He International Trading Co., Ltd. [China Manufacturers]
FDR2 Thermal overload relay
... .1-93A Theory: Thermal overload Relay 1. Application FDR2 Series overload relays apply to circuit of ... current 0.1A~93A for AC motor overload and open-phase protection during long time ... operation, can also be used focorresponding AC contactor for electromagnetic starter. This product has innovative, ... Thermal relay can be combined/connected with contactor or installed separately. Standard: IEC 60947-4 ...
Supplier: Yueqing Fengda Trade Co., Ltd. [China Manufacturers]
Electromagnetic contactor
... motors and ci. Electromagnetic Contactor 3TF41 For long distance ... overload or phase-failure. They are made according to IEC947-2, BS5424 & VDE0660. SPECIFICATIONS of 3TF/CJX1 Electromagnetic Contactor ... are chinese Electromagnetic Contactor manufacturer. Products including ...
Supplier: Yueqing Huaqi Import & Export Co., Ltd. [China Manufacturers]
3TF44 3TF45 Series AC contactor (magnetic contactor)
... 10 years 3TF44 45 Series AC contactorApplication 3TF series AC contactor are suitable in electrical system with AC 50/60Hz, ... starter with suitable thermal overload or phase-failure. They are made according to IEC947,BS5424 and VDE0660.The contactor is a straight ... All series products can be mounted by screws, le≤32A contactor also by installation rail.Specifications TypeRated hermal current(A)Rated ...
Supplier: Zhejiang Zhiming Electric Imp. & Exp. Co., Ltd. [China Manufacturers]
JRS2 Series Thermal Overload Relay
... of long or discontinuous long operation, used as overload protection and hasthe functions of breaking phase protection, ... manually get back. It can be fixed with contactor CJX1 together, also beindependtly fixed. The product conforms ... 2B12.5~20 2C16~25TypeNumberSetting range(A)For contactor TypeNumberSetting range(A)For contactorJRS2-32/Z1G4~6 ... more detail information. JRS2 Series Thermal Overload Relay
Supplier: Hefei Wolian Industrial Co., Ltd. [China Manufacturers]
CJX1(3TB/3TF)AC Contactor
... system. They can form electromagnetic starters with suitable thermal overload relays 3UA series to protect system and motors against ... overload or phase-failure. They are made according to IEC947-2, BS5424 &VDE0660. The contactor is a straight ... series products can be mounted by screws and le≤32A contactor also by insallation rail.ModelRated Thermal Current (A)Rated Operation ...
Supplier: Wenzhou Jerdin Electric Co., Ltd. [China Manufacturers]
Switching Capacitor Contactor
... dependable performance CJ149 series Switching Capacitor Contactor (hereinafter referred to as "Contactor")The contactor is suitable for the reactive power ... -on and compose with thermal overload relay as an integral to protect overload current operation.Nowadays, it is ... develop and design the technological requirements of switching contactor. There has been offered one technological requirements for ...
Supplier: Yueqing Aukeman Trading Co., Ltd. [China Manufacturers]
JR20 Thermal Overload Relay
JR20 Thermal Overload Relay 1.Frequency: 50/60Hz 2.Voltage up to 660V ... AC three-phase motor against overload and phase losing, and forming electromagnetic with starter CJ20 series AC contactor. It has functions of ... .150<2hheat state (Following the No.1 test) JR20 Thermal Overload Relay
Supplier: Zhejiang Tengen Imp. & Exp Co., Ltd. [China Manufacturers]
Ads by Google


Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.