Welcome to ECOL - Join Free - Sign In
Multi-channel Branch Feeder Meter, RS485 Communication
Multi-channel Branch Feeder Meter, RS485 Communication
Supplier Info
[China Supplier]
Contact Person : Mr. Zhou Jackey
Tel : 86-756-3629673,3629699
Fax : 86-756-3629600,3629700 Address: No.15, Keji 6 Road, Chuangxin Haian, Tangjia Hi-tech Zone, Zhuhai, Guangdong Zip: 519085 Country/Region: China (Mainland) Province/State: Guangdong
Product Detail
branch circuit power meter has HMI, measure volt, amp, watt, var,kWh, demand in 2 mains and 63 branch circuit. Support Modbus

PMAC201 Multi-channel Branch Circuit Power Meter

PMAC201 Branch Circuit Power Meter with following features:ØSmall size, one unit can monitor total 65 circuits ØSaving cost, saving space ØHigh reliability  ØModule design: Main module, CT module, DI module, HMI Display ModuleØIt can monitor harmonic, demand, neutral current ØCT measuring accuracy: Class 0.2% ØTwo kind of alarm methods: Voice and LED  ØMemory: 128M  Functions of PMAC201 Ø2 main circuits and Max. 63 branch circuits electrical parameters measuring and analysis ØDI/DO status monitoring ØTwo lever alarm information for U, I abnormal ØPower load analysis monitoring and pre-alarm ØStandard 7’’ HMI display data and schematic wiring, easy to operate ØSelect strip 1, 2 or 3 CT based on branch circuits ØEvent log: Record Max. 5000 events ØSupport RS485, MODBUS communication port.   MeasurementØ2 main circuits monitoring  Include: U, I, P, PF, F, kWh, Demand, Harmonic, Current unbalance ØMax. 3 strips CT, Max. 63 branch circuits monitoring  Include: I, P, PF, kWh, Demand

Technical Specification

Power supply

85~265V AC or 120~ 300VDC

MTBF

≥50000h

Service life

10 years

Rated voltage

220Vph-N, (optional 230V),

Range: 10%-120%, Accuracy: 0.5%

Rated current (Main circuit)

5A, Range: 1%-120% rated, Accuracy:0.5%

Rated current (Branch circuit)

50A, Range:1%-100% rated, Accuracy:0.5%

Frequency

50Hz, Range:45-60Hz, ±0.01Hz

Power factor

Accuracy of Main:1%,

Accuracy of Branch: 2%

Active/ Reactive energy

Accuracy of Main:1%,

Accuracy of Branch: 2%

Communication

RS485 port, support Modbus-RTU

Baudrate

4800, 9600, 19200bps

Status input

Wet impulse input, 220VAC, 60%-120% rated voltage

Relay capacity

250Vac/5A or 30Vdc/5A

Main Module

Metal case design, high grade EMC capability

                                                                         Sampling voltage, current, ON/ OFF status of mains & branch circuits

7 Inch HMI Display Module

DI (Digital Input) Module

  No need aux. contact, directly monitor branch circuit status

                                                                     Each status input has a indictor light.

CT (Current Transformer) Module

  Suitable to install in cabinet 600mm

CT accuracy Class 0.2 to assure accuracy  

1 strip has 21 CTs

Schematic  

Dimension

Order information

Model

Description

PMAC201M

PMAC201 main module

PMAC201V

Display module

PMAC201C

CT module (Max 3 strip, each strip with 21 CT)

PMAC201K

Status input (Max 3 strip)

Remark:

1. PMAC201C can monitor Max 21 outgoing circuit, PMAC201M can connect Max 3 strip PMAC201C.

2. PMAC201K can monitor 21 circuit status input. And PMAC201M can connect Max 3 strip PMAC201C.

Multi-channel Branch Feeder Meter, RS485 Communication

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.