Welcome to ECOL - Join Free - Sign In
PVC Insulated Power Cable
PVC Insulated Power Cable
Supplier Info
[China Supplier]
Contact Person : Mr. Qian Allen
Tel : 86-512-52265697
Fax : 86-512-52661724
Product Detail
Power cable of rating voltage 0.6/1KV PVC insulation and power cables high quality products at competitive price

1 Conductor:Copper or Aluminium 2 Insulation:PVC or XLPE 3 Voltage:Low/Medium/High Voltage 4 Standard:IEC 60502,GB/T 12706

 Technical Parameters of our Power Cable 

1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890

2). Detailed description or construction:

    * Conductor: compacted or uncompacted copper or aluminium

    * Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)

    * Filler: Polypropylene filament with lapped binding tape

    * Binder: Binding tape

    * Inner sheath: Polyvinyl chloride (PVC)

    * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)

    *Sheath: Polyvinyl chloride (PVC)

3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:

    U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV.

4). Voltage:

     0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV

    In the voltage designation of cables U0/U(Um):

        * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

        * U is the rated power frequency voltage between conductors for which the cable is designed;

        * Um is the maximum value of the "highest system voltage" for which the equipment maybe used.

5). Application:

     For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.

6). Marking: According to the customers' requirements

7). Nominal cross-sectional areas:

1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2

Operating characteristic:
Tating voltageU./U: 0.6/1KV Long-term working temperature of cable: PVC insulation 70°CMinimum laying temperature of cables: 0°C Minimum curving semidiamenter of cables:Single core nonarmoured cables: 15DMultiple nonarmoured cables: 12D Single core armoured cables: 20DMultiple armoured cables: 15D Remarks: S is actual outer diameter of cables. Unit:mm

specification

Type(Cu,Al)

Quantity of core

Nominal section(mm2)

VV VV22 VV23

YJV YJV22 YJV23

1

1.5-630

(armoured cable 10-630)

2

1.5-185

(armoured cable 4-185)

3

1.5-300

(armoured cable 4-300)

4

3+1

1.5-300

(armoured cable 4-300)

5

3+2

4+1

1.5-300\

(armoured cable 4-300)

Ads by Google