Welcome to ECOL - Join Free - Sign In
0.6/1kV XLPE Insulated Power Cable
0.6/1kV XLPE Insulated Power Cable
Supplier Info
[China Supplier]
Contact Person : Mr. LEE ANDY
Tel : 86-577-62730207
Fax : 86-577-62730507
Product Detail
laying indoors,in tunnel,in cable trench or direct in ground,able to bear external mechanical forces,able to bear large pulling

0.6/1kV XLPE insulated power cable

0.6/1kV Power Cable:

Cu(Al)/XLPE/PVC, Cu(Al)/XLPE/STP/PVC, Cu(Al)/XLPE/SWA/PVC,Cu(Al)/PVC/PVC, Cu(Al)/PVC/STP/PVC, Cu(Al)/PVC/SWA/PVC,NZXY, NZXBY, NZX, NYY, NYBY

1). Standard: IEC60502, GB/T12706

2). Voltage: 0.6/1kV

3). Nominal cross-sectional areas: 1.5mm2, 2.5 mm2, 4 mm2, 6 mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2

4). Production range: Single core cable from 1.5mm2 to 800mm2; Multi-core cable from 1.5mm2 to 400mm2

5). Operating characteristics:

Rated power-frequency voltage U0/U: 0.6/1kV

Max. Permissible continuous operating temperature of conductor: 90°C

Max. Short-circuit temperature of the conductor shall not exceed(Max. 5 seconds duration): 250°C

The ambient temperature under installations should not be below 0 °C

The bending radius of single core cable should not be less than 20 times of the cable diameter; The bending radius of multi-core cable should not be less than 15 times of the cable diameter.

Type

Designation

Applications

YJV    YJLV

Copper/Aluminium conductor, XLPE insulated, PVC sheathed power cable

For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct

YJY   YJLY

Copper/Aluminium conductor, XLPE insulated, PE sheathed power cable

YJV22   YJLV22

Copper/Aluminium conductor, XLPE insulated, steel tape armoured, PVC sheathed power cable

For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force

YJV23   YJLV23

Copper/Aluminium conductor, XLPE insulated, steel tape armoured, PE sheathed power cable

YJV32   YJLV32

Copper/Aluminium conductor, XLPE insulated, steel wire armoured, PVC sheathed power cable

For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, able to bear large pulling force

YJV33   YJLV33

Copper/Aluminium conductor, XLPE insulated, steel wire armoured, PE sheathed power cable

Note: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied

0.6/1kV XLPE Insulated Power Cable

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.