Welcome to ECOL - Join Free - Sign In
FKW18-12/24/40.5 Outdoor HV Load Break Switch
FKW18-12/24/40.5 Outdoor HV Load Break Switch
Supplier Info
[China Supplier]
Contact Person : Ms. Chen yuhui
Tel : 0086-577-27898885
Fax : 0086-577-62538979
Product Detail
load break switch 1.Altitude: 3000m 2.Ambient temperature:-25~+40 3.Wind speed: 35m/s 4.Pollution degree: IV

load break switch

FKW18-12/24/40.5 Outdoor HV Load Break Switch

Verified Information This information is Verified by Bureau Veritas and is valid for the following period: 2013/01/21 --- 2014/01/21 All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >> Production Capacity: Product line name Production Line Capacity Actual Units Produced(Previous Year)
Wind turbine, SF6 CB, Outdoor disconnect switch, Outdoor AC VCB USD 30,450,000 Per Month confidential
Export Market Distribution: Market Revenue(Previous Year) Total Revenue (%)
North America confidential 0.3
South America confidential 1.1
Eastern Europe confidential 10.3
Southeast Asia confidential 11.6
Africa confidential 1.6
Oceania confidential 0.2
Mid East confidential 1.2
Eastern Asia confidential 0.1
Western Europe confidential 0.1
Northern Europe confidential 1.0
Southern Europe confidential 0.8
South Asia confidential 1.4
Domestic Market confidential 70.3
Production Machinery: Machine Name Brand & Model No. Quantity Number of Year(s) Used Condition
Assembly line No information 20 3.0 Acceptable
Welding manipulator No information 1 3.0 Acceptable
Printing machine PF09880C 1 3.0 Acceptable
Painting line No information 1 2.0 Acceptable
CNC bending machine ME-40 2 3.0 Acceptable
CNC cutting machine No information 1 3.0 Acceptable
CNC mechanical turret punch press No information 1 2.0 Acceptable
Testing Machinery: Machine Name Brand & Model No. Quantity Number of Year(s) Used Condition
Metal-enclosed Compact Switchgear XGN74-12 1 2.0 Acceptable
High voltage switchgear intelligent integrated test system HYZC-20 4 2.0 Acceptable
Switch mechanical properties tester XHR-8(B) 6 3.0 Acceptable
Withstand voltage tester SH2132 10 3.0 Acceptable
High voltage test transformer No information 10 3.0 Acceptable
Grounding resistance tester WB2678A 10 3.0 Acceptable
Production Flow: 1.Punching 2.Cutting 3.Bending 4.Welding 5.Painting line 6.Assembly line 7.Testing 8.Packaging Certification: Certified Picture Certification Name Certified By Certificate No. Product Name & Model No. Available Date-Expired Date
ISO 9001:2008 VOUCHING TECHNICAL INSPECTION LTD. CNAS VOUCHING TECHNICAL INSPECTION LTD. CNAS Scope: Design, manufacture, sale and service of 40.5kV and below high voltage switchgear; 0.66kV and below low voltage switchgear; 40.5kV and below prefabricated substation; 126 kV and below outdoor/indoor high-voltage circuit breaker; 40.5kV and below high-voltage load break switch, high-voltage load break switch combined fuse, high-voltage cable conjunction box; 252Kv and below disconnect switch and earthing switch; power automation system & equipment (monitor, reply protection, communication) and software; wind turbine generator system; DC power supply panel; 40.5kV and below oil-immersed power transformer; 126kV and below gas-insulated switchgear (GIS) 2010/06/28 --- 2013/06/28
ISO 14001:2004 VOUCHING TECHNICAL INSPECTION LTD. CNAS 0410E10170R2M Scope: Environmental management activities and sites involved in production process and management of 40.5kV and below high voltage switchgear; 0.66kV and below low voltage switchgear; 40.5kV and below prefabricated substation; 126 kV and below outdoor/indoor high-voltage circuit breaker; 40.5kV and below high-voltage load break switch, high-voltage load break switch combined fuse, high-voltage cable conjunction box; 252Kv and below disconnect switch and earthing switch; power automation system & equipment (monitor, reply protection, communication) and software; wind turbine generator system; DC power supply panel; 40.5kV and below oil-immersed power transformer; 126kV and below gas-insulated switchgear (GIS) 2010/06/28 --- 2013/06/28
OHSAS18001:1999 VOUCHING TECHNICAL INSPECTION LTD. CNAS 0410S10171R0M Scope: Occupational Health and safety management activities and site involved in production process and management of 40.5kV and below high voltage switchgear; 0.66kV and below low voltage switchgear; 40.5kV and below prefabricated substation; 126 kV and below outdoor/indoor high-voltage circuit breaker; 40.5kV and below high-voltage load break switch, high-voltage load break switch combined fuse, high-voltage cable conjunction box; 252Kv and below disconnect switch and earthing switch; power automation system & equipment (monitor, reply protection, communication) and software; wind turbine generator system; DC power supply panel; 40.5kV and below oil-immersed power transformer; 126kV and below gas-insulated switchgear (GIS) 2010/06/28 --- 2013/06/28
CE MORGARN CE-07-1009-01 Low Voltage Withdrawable Switchgear GCS-3200A-1000A 2007/10/09 --- 2049/12/31
KEMA KEMA TIC 2091-11 Earthing switch JN15-24/31, 5-275mm 24 kV - 31, 5 kA - 80 kApeak - 50 Hz 2012/08/16 --- 2049/12/31
KEMA KEMA TIC 1045-11 SF6 outdoor circuit-breaker LW 36B-145/T3150/40 145 kV - 3150 A - 50 Hz 2011/10/19 --- 2049/12/31
KEMA KEMA TDT 2183-10 Three-phase outdoor disconnector GW4-145/2000-40 145kV - 2000 A 40 kA - 50 Hz 2011/01/18 --- 2049/12/31
CCC CQC 2003010301070972 Low-voltage Switchgear Assemblies MNS Main bus: In=3200A~2500A,Icw=80kA; Distribution bus: In=1000A,Icw=50kA;Ue=380V;Ui=660V;50Hz;IP40 2008/01/09 --- 2049/12/31
CCC CQC 2007010301253968 Low-voltage Switchgear Assemblies GCK Main bus: In=3200A~1000A,Icw=50kA; Distribution bus: In=1250A~400A,Icw=50kA;Ue=380V,Ui=660V;50Hz;IP30 2007/11/09 --- 2049/12/31
Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.