This working station contain circulation pump, compasion vessel, and flowmeter for solar water heater
Working principle:
1) When the temperature of the Separated solar water heaterheat collector reaches the set value, the controller will make shall the circulation pump work automatically. 2) The circulation pump makes heat-conducting liquid circulate automatically. 3) The heat-conducting liquid transfers heat to water by the heat exchanger in the tank. 4) In case the temperature of the circulation pump does not reach the set value, the circulation pump will be shut automatically. 5) In case the temperature of the tank does not reach TM ax, then start the auxiliary heating device.
Working Station for Solar Water Heater