Welcome to ECOL - Join Free - Sign In
WT20C digital gauss meter tesla meter
WT20C digital gauss meter tesla meter
Supplier Info
[China Supplier]
Contact Person : Mr. Sun Simon
Tel : 86-370-4117725
Fax : 86-370-4121881
Product Detail
Factory Outlets many patterns available

Introduction

The Tesla meter is a special instrument used for inspecting & checking flux density ,which is also one of the most universally devices in the field of magnetic measurement.

   Model WT20D digital Tesla meter is controlled by the SCM, which is suitable for handle operation.It can be used to measure DC or AC magnetic field and flux dencity.The device can be carried on one’s person. It is characterized by its wide measuring range,simple operation and clear display. It is still added with the function of maintenance such as holding Measure Value/Peak Value, As mT or Gs unit of display can be change over, Measuring range of 200mT or 2000mT can be chose, and others that as resetting zero by key and so on. The power is one piece of battery 9V. It can be used continually about 20 hours.

Reality Working Domain:

1)       Magnetic field distribution of material surface

2)       Working in the magnetic field produced from some instrumentssuch as iron-removing device,magnet-selecting machine, magnet chuck, magnet spool and demagnetizing coil

3)       Leakage Magnetic iron-surface

Main Technical Parameters

Rang: 0~200mT~2000mT

Accuracy: ±5%

Sensitivity: 0.01mT, 0.1mT

AC Magnet Field: 50-200Hz

Temperature of environment: 5°C-40°C

Relative humidity: 20%-80%(no condensation)

Power Supply: Battery 9V, constant DC power

Dimension:  230mm×205mm×80mm

Weight: N.W: 1.0kg G.W:1.2kg

Display: 4½ LCD

Shape of the device:

Range ChangingDC/AC Switch mT/Gs Unit ChangingSensor Connecting Real/Hold Value SwitchZero/Reset ReadingLED Screen 

Screen of Display

Manipulation Procedure

1. Connect Power

2. Insert the Hall probe into the socket on the panel (according to the arrow marking the sensor).

     

3. Press the key of the Power On/OFF in the panel and the digital display screen should display zero.

Select a suitable measurement range

4. Press the key RANGE switchover again and again , the measurement range would be transformed within 0-200 mT or 0-2000 mT.

5. Select DC/AC mode

Press the key DC/AC switchover again and again , the DC/AC mode would be selected.

6. Select display unit

Press the key(5) of conversion , the display unit would be transformed from mT to Gs.

7. Reset zero

Keep the sensor far away from magnetic field what it is not in the state of holding .If the display screen should not show “000”.you must press the key(7) to adjust it to zero.

Note: After change over the measurement range or transform the AC/DC mode , you all need to reset zero.

 

8. Measurement of Peak-value holding

Press the key(6) to change over normal measurement or Peak-value holding .

9. Loosen the cap of the Hall probe (see upper Fig).Place the effective position of Hall probe to touch on the surface of the resting material tightly (DC magnetic field) or at zone of measured magnetic field. The screen(8) will show the value of the magnetic field.

10. Reset Peak-value holding

When keeping the Peak-value holding , you need to measure new peak value and the forecast value will be lower forecast. Thus you could press the Reset button(7) to make it show a new peak value.

11. If the measurement is finished, the cap should be screwed up. It may be better to remove the battery from the case to prolong its time of use.

12. The Hall probe can be replacable .The difference from original probe to others is 2%.

Note: 0.1mT=1Gs       1T=10000Gs

Maintenance and Notes

As the statu of measuring ,if the instrument could not be adjusted to the zero or no display value. You’ll first check the power supply whether it is in the course of nature. Than check the probe whether it is normal or damaged. If the connecting wires are ruptured you could connected it according to the right Fig. Such terminal 1,2 are current, No. 4 and No.5 are terminals of voltage.

If you don’t find an damage in it , please send it to our company . It’s maybe wrong within the circuits.

The probe can’t burden force ,be cracked and squeezed.While making the zero adjustment, the probe should be placed far away from the magnetic field for fear of the measurement error.The instrument is guaranteed to keep in good repair for 18 months except the probe.Do not use the instrument in unappropriate conditions.If you find the value of testing shows errors in the states of measurement, you could loosen the handle of the probe to adjust the screw of the resistance tinily.

If don’t ensure that the instrument is operated correctly as described below, there would be error or

mistake.

1,Don’t attempt to repair, or disassemble, and any reconstruct this instrument.

2,  Use only recommended power accessories.

3,  Don’t connect the terminals of the outer power supply reversely. the inner is plus, the outer is minus.

4,  Don’t drop this instrument or the probe down ground. It’ll be damaged by strong vibration.

5,  Do not allow hands or other objects with dirt to touch the probe.

6,  Avoid using, placing or storing the instrument in places subject to strong sunlight or high temperature, as well as humidity, water, oil, rust air, vibration and others.

7,  It would be used and stored up in temperature range

8,  You should not move the instrument rapidly between high and low temperature to avoid condensation.

9,  Never place the instrument in the places close to the machine generating strong magnetic field, such as magnet-charger, demagnetize coil, microwave oven, electric welding equipment electric motor and etc.

10,In conclusion, we suggest you calibrate the instrument in time.

   

WT20C digital gauss meter tesla meter

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.