XXH-1205 radiation testing equipment 1. The controller works without noise 2. Suitable with most brand of power generator

Portable XXH-1205 radiation testing equipment

Construction

 X-ray headControlleraccessories

Main technical parameters

X-ray tube voltage

40-120kV

X-ray tube current

5mA

Max. penetration  -A3 steel

7~8 mm(5min exposure,D≥1.5)

Tube voltage stability

±5%

Tube current stability

±5%

Generator external size

Φ130×580mm

Generator weight

8kg

Controller external size

390×380×170mm (including handle)

Controller weight:

12kg

Input power:

220V±10%,AC 50Hz, capability≥2.5kVA

Operating  temperature

-20°C~+40°C

Accessories

No.

Nmae

Count

1

Power cable(3×2.5 cores,   10m)

1

2

Controller and tube head Connection

(10×2.5 cores  25m)

1

3

Fuses 2A,10A,20A

5 pieces every

4

Ground cable(5m)

1

5

Power switch key

2

6

Door interlock cable plug

1

The merit of HR-900 X-ray controller 

1,  Use IGBT working in high frequency instead of SCR. So the X-ray tube voltage and current keeps very stable even if the AC220 power supply voltage is violence changing in a wide range.

2,  Has a higher power factor than controller with SCR.

3,  Suitable with most brand of power generator

4,  Has a real time clock and EEPROM in the controller that can remember operation record automaticaly. The controller can decide whether season is needed by this record.

5,  Both the tube head and the controller are strong and endurance.

6, The controller works withou noise

The compare of controller with IGBT and controller with SCR

 

Ordinary controller with SCR.

HR-900 controller with IGBT

Power factor

0.23-0.45

0.66

Power factor constant

No, power factor decrease along with tube voltage decrease

Yes

power consumption

High

Low

Generator (When There is not power source in the open air)

Suitable with a few brand of power generator

Need adjust synchronization

Need large power generator, normal 5000W

Waveform of controller instability

Suitable with most brand of power generator

No need adjust synchronization

Need small power generator

Waveform of controller stability

Output tube voltage influenced by power fluctuations

Large

No influenced

Both AC and DC

No

Yes

Number of adjustment potentiometer

6

2

Limiting output current function

No

Yes

Capacity of resisting impact of fault tube

weak

Because high voltage generator primary coil can automatically limit current. So capacity of resisting impact is strong. The controller almost is not influenced by high voltage fault and X-Ray tube fault.

Automatic season according to stopping time

No

Yes

No power off until full cooling time. Force wind cooling 

No

Yes

Directly shut off high voltage by key

No

Yes