Welcome to ECOL - Join Free - Sign In
Insulation Piercing Connectors Cable fittings
Insulation Piercing Connectors Cable fittings
Supplier Info
[China Supplier]
Contact Person : Mr. guo peter
Tel : 86-577-62728800
Fax : 86-577-62738811
Product Detail
Insulation Piercing Connectors Cable fittings Effusion resisrant fireproff waterproof

Insulation Piercing Connectors Cable fittings

Material

body

Nylon 66

Teeth/blade

Copper tinned or Aluminum

bolt

Hot dip galvanized

Sheer head

Zinc alloy

Main technical parameter:

Type

Main line section(mm2)

Branch section(mm2)

piercing depth

Normal current(A)

Outline size(mm)

Weight(g)

KN101

1.5~2.5

1.5~10

1.5~2

55

27×41×62

55

KNEP

16~95

1.5~10

1~2

55

27×41×62

55

KN2-95

16~95

4~35(50)

1.5~2

157

46x52x87

160

KN2-150

50~150

6~35(50)

1.5~2.5

157

46x52x87

162

KN3-95

25~95

25~95

1.5~2

214

50×61×100

198

KN4-150

(35)50~150

(35)50~150

1.5~2.5

316

50×61×100

219

KN6

120~240

25~120

1.5~2.5

211

52×68×100

360

KN7

150~240

10~25

1.5~2.5

102

52×68×100

336

KN240

95~240

95~240

1.5~2.5

425

83×130×130

1040

KN300

300

Any size

1.5~2.5

425

83×130×130

1040

KN400

120~400

Any size

1.5~2.5

425

83×130×130

1040

Please contact us for special specification and type.

Feature:1) Simple installation, small contact resistance and low temperature rise of the clamp

2) The applicable voltage is 1KV, less than 1KV and 10KV.

3) Piercing connector, simple installation, need not strip the cable coat.

4) Moment nut, piercing pressure is constant, keep good electric connection and make no damage to lead.

5) Self-seam frame, waterproof, waterproof, and anti-corrosion, extend the using life of Insulated lead and connector.

6) Adopted special connecting tablet, apply to joint of Cu (Ai) and Cu (Ai) or Cu and Ai

7) Small electric connection resistance, impulse current can be up to 15KA.

8) Special insulated case body, resistance to illumination and environmental aging, the insulation strength can up to 6kV.

9) AAC surface design, apply to connection with the same (different) diameter, wide connection scope (0.75 mm2-400 mm2)

10) Can be installed with online line and can work without power.

Mainly application:                                              

1) The connection of structural distribution system,

2)The connection of airy low voltage insulated cable

3) The connection of indoor electric wire

4)The connection of distribution system of street lamp.

 

Insulation Piercing Connectors Cable fittings

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.