The turbidity monitor is based on a membrane-capped amperometric principle. It is used for continuous measurement of the turbidity present when metering turbidity disinfectants.
The on-line turbidity monitor should be used only to determine the amount of turbidity in oxidation of drinking water, landfill leachate, contaminated ground water; Disinfection of cooling, service and production water in the pharmaceutical, food and beverages industry as well as in swimming pools or water of a similar quality; Deodorization (gas scrubber) in municipal and industrial purification plants; Dechlorination in chemical processes; chemical bleaching in the timber, paper, textile and mineral material industry; Organic synthesis in the chemical, pharmaceutical, and cosmetics industry.
Please note that for regulation tasks, the response time T90 is 30s!
In order to guarantee the flow parameters, the sensor should be used in the on-line probe housing to control the flow rate of sample to 30L/h. (20L/h~100L/h).
Technical Date
Measured variable: turbidity
Application:
Oxidation of drinking water, landfill leachate, contaminated ground water
Disinfection of cooling, service, and production water in the pharmaceutical, food and beverages industry as well as in swimming pools
Deodorization (gas scrubber) in municipal and industrial purification plants
Dechlorination in chemical processes
Chemical bleaching in the timber, paper, textile and mineral materials industry
Organic synthesis in the chemical, pharmaceutical and cosmetics industry
Measuring range: 0.00-10.0 mg/L or NTU
0.0-100.0 ppm or NTU
Reaction time: T90 reaction <30s
Measuring resolution: 0.01mg/l
Measuring accuracy: 0.2% F.S.
Alarm function: high and low limit absolute alarm, PID control output
pH range: 1.0~11.0
Temperature compensation range: 0~50°C,. No sharp rises in temperature.
No quick changes in temperature allowed.
Storage temperature and humidity : Frost-free between 5~50°C, 10~90%RH
Solution: corresponds to lower measurement range limit.
Max. Pressure of probe housing: Max. 1bar ( free flow outlet)
Flow rate of probe housing: optimum 30 L/h.
Minimum: 20 L/h
Maximum: 100 L/h
Cross sensitivity: oxidizing reagents e.g. bromine, bromamine, peracetic acid, ozone, chlorine dioxide, permanganates results in false positive results.
Reducing reagents like sulphides, sulphites, thiosulphates and hydrazine result in false negative results.
Conductivity of water sample: 50~5000μS/cm
Service life of membrane cap: Typically 6 months, depending on water quality
Material of membrane cap: Membrane cap: PVDF, PVC
Electrode adaptor: PVC-C
Supply power: 85-265VAC/50-60Hz, <6w
Enclosure rating: IP65