Features:
H782 This meter is a portable and specialized process verification instrument, which presents as a digital verification meter that has both digital multimeter and signal
source function, and can measure and output signal simultaneously. Its large liquid
crystal digital display can show and measure the output signal value at the same
time, and it is equipped with backlight which makes the user easier to read the value.
It uses large capacity rechargeable battery pack and is featured with low voltage
indication. Charging and operating for this instrument can be conducted
simultaneously (with a charger). Signal output and measurement function of the
instrument is mainly designed for on-site verification and service of an instrument in
industrial automation field. This instrument is also featured with multimeter
function, which makes it an ideal option for field meterman, computer distributed
control system maintainer, meter mounter, and can be used as a multimeter by the
meterman.
Precision 1000V, 400 mA digital multimeter • Measure AC and DC volts, AC and DC current, resistance, continuity, frequency
and temperature and break-and-make, diode and triode test.• 0.1% DC voltage accuracy• 0.1% DC current accuracy• True rms ac voltage measurement to 400Hz• Frequency measurement to 200kHz• Diode test and continuity beeper DC current source/loop calibrator• 20 mA current source/simulator• Simultaneous mA
SpecificationsCurrent Measurement | Range: | 0-400mA DC | 0-400mA AC | ||||
Resolution: | 0.1 mA | 0.1 mA | |||||
Accuracy: | 0.1% Rdg + 5LSD | 1% Rdg + 5LSD | |||||
Voltage measurement | Range: | 1000VDC | 0-700 VAC | ||||
Resolution: | 1.0 V | 1.0 V | |||||
Accuracy: | 0.1% Rdg+5LSD | 0.8% Rdg + 5LSD | |||||
Frequency measurement | 20Hz to 50 kHz, 0.05% + 5LSD | ||||||
Resistance measurement | to 4 MΩ , 0.3% Rdg + 5 LSD; 4 MΩ to 40 MΩ 0.5% + 50 LSD | ||||||
Capacitance measurement | to 100 F , 2.0 % Rdg + 10LSD | ||||||
Temperature measurement | K-type Thermocouple (optional). | ||||||
Diode measurement | 2.4 V shows diode voltage drop | ||||||
Current Sourcing | Range: | 0-22 mA | |||||
Accuracy | 0.1% Rdg + 5LSD | ||||||
Drive Capability: | 1000 Ω @ 20 mA | ||||||
DC voltage signal output | Range: | 10VDC | 100mVDC | ||||
Resolution: | 10mV | 0.1mV | |||||
Accuracy: | 0.1% Rdg+5LSD | 0.1% Rdg+5LSD | |||||
Frequency signal output | Range: | 100Hz | 1KHz | 10KHz | |||
Resolution: | 0.01Hz | 0.1Hz | 1Hz | ||||
Accuracy: | 0.1Hz | 0.5Hz | 5Hz | ||||
24DC voltage Sourcing | Accuracy: 2% ; Drive Capability: 30 mA | ||||||
Size | 55 x 92 x 195 mm |
Weight | 600 g |
Batteries | Ni – MH rechargeable batteries |
Warranty | 2 years |
Battery Life | 50 hours typical (measurement), 12 hours typical (sourcing 12 mA) |
Shock & Vibration | Random, 2g, 5-500 Hz |
1 meter drop test | |
Auto step, auto ramp | Yes |
Process Calibration Multimeter