Fluke Process Multimeter :
• In-circuit measurement of 0-24 mA dc and up to 99.9 mA dc using aremotely connected clamp via extension cable• 0-24 mA dc sourcing and simulating• 0-10 V dc sourcing • Loop power supply 24 V dc output• 0-30 V dc measurement • Scaled mA output • Simultaneous mA measurement via detachable clamp and mAsourcing • 250 Ω HART resistor for mA source• Electronic zero• Percentage span (0-100 %)• Hold• Auto power off (battery saver)• Display backlight• Measurement spotlight LED
The Meter comes with:• Four AA alkaline batteries (installed)• Soft carrying case• TL75 test leads• AC 72 detachable clip• TL 940 mini hook test leads• Instruction sheet
SpecificationsElectrical SpecificationsCurrent MeasurementWith JawRanges ................................ 0-20.99 mA; 21-100 mAResolution............................ 0.01 mA; 0.1 mAAccuracy.............................. 0.2 % + 5 counts;1 % + 5 countsIn CircuitRange.................................. 0-24 mAResolution............................ 0.01 mAAccuracy.............................. 0.2 % + 2 countsCurrent SourceRange.................................. 0-24 mAResolution............................ 0.01 mAAccuracy.............................. 0.2 % + 2 countsmA Drive..............................24 mA into 1000 ΩCurrent SimulateRange.................................. 0-24 mAResolution............................ 0.01 mAAccuracy.............................. 0.2 % + 2 countsMaximum Voltage................50 VDC Voltage Measurement:Range.................................. 0-30 VResolution............................ 0.01 VAccuracy.............................. 0.2 % + 2 countsDC voltage source :Range.................................. 0-10 VResolution............................ 0.01 VAccuracy.............................. 0.2 % + 2 countsmA Drive..............................2 mA max all conditionsmA IN/OUT:Sourcing range .................... 0-24 mASourcing resolution.............. 0.01 mASourcing accuracy ............... 0.2 % + 2 countsMeasurement range............. 0-24 mAMeasurement resolution ...... 0.01 mAMeasurement accuracy .......1 % FSScaled mA current output to mA current input from the Jaw:Range.................................. 0-24 mAResolution............................ 0.01 mAAccuracy..............................1 % FSResponse speed ........................ 2 times per secondDC Loop Power..........................24 VInfluence of Earth’s Field............<0.20 mABatteries..................................... 4 1.5 V, Alkaline , IEC LR6Working hours............................ 12 hours @ 12 mA sourced into 500 ΩMechanical SpecificationsSize (H X W X L) ....................... 43.7 mm x 70 mm x 246.2 mmWeight........................................410 gEnvironmental SpecificationsOperating Temperature ............. -10 ~50 °CStorage Temperature................. -25 ~60 °COperating Humidity....................<90 % RH @ <30 °C ;<75 % RH @ 30 ~50 °COperating Altitude...................... 0 ~ 2000 mIP Rating.................................... IP 40Vibration Requirements .............Random 2 g, 5 to 500 HzDrop Test Requirements ............1 meter drop test (except the jaw)EMI, RFI, EMC...........................Meets all applicable requirements inEN61326-1Note: For current measurement w/jaw, add1 mA to specification for EMC field strengthsof 1 V/m up to 3 V/m.Temperature Coefficients .......... 0.1(/ °C X Specified accuracy forTemperature <18 °C or > 28 °C)Standards and Agency Approval SpecificationsAll products certified to the following:EN / IEC 61010-1, EN / IEC 61010-2-032Agency Approvals P ), ;Miscellaneous Specifications:Power Requirements..................Four AA batteries, Alkaline , IEC LR6Automatic Time-out (Power).......After 15 minutes ±1 minutesAutomatic Time-out (Backlight) ..After 2 minutes ±10 secondsAutomatic Time-out(Measurement Spotlight)............After 2 minutes ±10 seconds
---------------------------------------------------------------------
-----------------------------------------------------
Shipment & Feedback:
Fluke Process Multimeter