Welcome to ECOL - Join Free - Sign In
BYZ810 Stackable Single channel syringe pump
BYZ810 Stackable Single channel syringe pump
Supplier Info
[China Supplier]
Contact Person : Ms. Xue Andrea
Tel : 86-29-85338446
Fax : 86-29-85338446
Product Detail
1.Freely Stackable 2.maximum 8 channels 3.Three working modes 4.Voice Alarm system 5.Large LCD screen display

 BYZ-810 Stackable Single syringe pump 

Features & Functions:

1. Freely Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions, which have a wide range of clinical applications.

3. Stackable to be the maximum 8 channels.4. Transfer the message between the Nurse-call System and the pumps.

5. Three working modes: rate mode, time-volume mode, dosage-weight mode.

6. Unique Voice Alarm system and accurate injection rate make the injection process safer and more reliable.

7. Automatically calibration and compatible with any brand syringes.

8. Large LCD screen displays working status.

9. KVO and Bolus functions.

Technical parameters:

Product name

Stackable syringe pump BYZ-810

Unique Voice Al arm system

The device triggered the voice prompt and stop injection automatically when there is any malfunction, making the infusion process safer and more reliable.

Flow rate

50ml syringe:0.1~1500ml/h;

30ml syringe:0.1~900.0ml/h;

20ml syringe:0.1~600.0ml/h;

10ml syringe:0.1~300.0ml/h

The range of limiting volume

0~999.9ml

The range of injected volume

0~9999.9ml

Accuracy of flow rate

Within ±3%(Choose the syringe of specified manufacturer correctly. This accuracy of flow rate is not including the errors of syringe itself.)

Purge rate

Purge rate of 50ml syringe:1500ml/h;

Purge rate of 30ml syringe:900.0ml/h;

Purge rate of 20ml syringe:600.0ml/h;

Purge rate of 10ml syringe:300.0ml/h

Alarm and warms

The pump can give out alarming when injection soon finish, injection finishing, injection of limited amount finished, injection is blocked, syringe falls off, syringe is improperly installed, setting error, AC power has been pulled out, low battery and so on.  

Injection blocked

Choose in the three kinds of occlusion alarm pressure according to the clinical requirements(High,Medium,Low)

KVO rate

1ml/h

Fuse specification

F1AL/250V ,two fuses(installed inside pump)

Operating power

AC100~240.0V, 50/60Hz,  Power:≤30VA

Internal rechargeable battery: DC 11.1V,capacity≥1600mAh. The device could work constantly more than 4 hour at medium speed running mode, after the battery charged for 10 hours.

Operating environment

temperature:+5~+40°C,  relative humidity:20~90%

Storing environment

temperature:-30°C~+55, relative humidity:≤95%, ( No condensation state )

Atmospheric pressure

860hPa~1060hPa

Safety level

Class II with insulated enclosure, internal power supply, BF-type continuous normal running equipment.

IP grade

IPX1

Dimensions

280(L)×210(W)×130(H)(mm)

Weight

2.2kg

Accessories

Power line,operating manual,warranty card,product certification.

BYZ810 Stackable Single channel syringe pump