On-off liquid level controller, 1)modular structure output 2)on-off control style 3) Accuracy: +-0.2%FS+1 digit 4) CE,ROHS

KH101 is ON-OFF Intelligent Process Controller used the advanced SMT technology, Modular Structure, to be designed high quality and performance, universal use, to be aimed to measure and control accurately the processes in various industry applications for temperature, humidity, pressure, level, weight, flow etc.

Features  

SMT technology, advanced Modular Structure,Universal input signal: T.C. RTD, mA DC, mV DC….etcHigh accuracy: +-(0.2%FS+1)85-240VAC, 24VDC power supply optionDual windows, four digit, 7 segment LED displayControl way: two position or three position ON-OFF controlCould select relay, SSR drive, SCR as main control outputCould select 5VDC, 12VDC, 24VDC as auxiliary power supply for sensorCould select 4-20mA, 0-10mA current retransmission for other device.Alarm can be set and configured, up to four stages.The user can access the data on the screen as well as on site from a remote place via RS485, RS232 serial interface.MODBUS-RTU communication protocol are available for configuration with MCGS and others professional software. Max baudrate can be up to 19200

General data of KH101 process controller

Power Supply

85-240VAC,-15%,+10%/50-60HZ

Power Consumption

≤5W

Accuracy Class

0.2%FS

Working Environment

temperature: 0-50oC

humidity: 0-85%RH

Display Accuracy

0.1oC

Connection Method

Screw fixing

Technical Specification

KH-1-2 3 45-6 7 8 9-10

SN

Name

Description

1

Outer Size

A:96X96mm, B.48x96mm, C.96X48mm, D.160X80MM, E.80X160mm,F,72X72mm, G.48x48mm

2.

Item No.

KH101-

3.

Control Method

1: On-off control

4.

Input Method

1: Thermocouple 2: RTD 3:Linear current 4:Linear voltage 5:customized

5.

Output Method

Modular output

6.

Alarm Method

1: High limit alarm 2: Low limit alarm 3: higher limit alarm 4:lower limit alarm 5:Positive deviation 6: negative deviation ( max. 3 module output)

7.

Input type

1: K,S,E,J,T,B,N 2: PT100, CU50, CU100 3:0-5V, 1-5V 4:0-10mA 5:4-20mA

8.

Output type

R1/R2: Relay contact output module

W1:SCR non-contact output module

G:SSR driving voltage output module

K1:Single circuit SCR crossing zero trigger output module

K2:Double circuit SCR crossing zero trigger output module

I1:Poto electronic isolated current transmission output module

S1:Poto electronic isolated RS485 communication interface

S2:Poto electronic isolated RS232 communication interface

U1/U2/U3: isolated 5V/12V/24VDC feed

9

Alarm type

R1/R2 :Relay contract output W1:SCR non-contact output K1/K2: SCR crossing zero trigger output(control thyristor) G:SSR driving voltage output (to driving SSR)

 

10.

Communication type

I1, S1, S2

 

 

 

As a professional and experienced manufacturer, we suplly process controller, temperature controller, PID temperature controller, Program temperature controller, PID process controller, program process controller,on-off process controller.

As a proffesional and experienced manufacturer, we supply high performance and quality liquid level controller, level controller, PID level controller, level meter.

liquid level controller

Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.