Welcome to ECOL - Join Free - Sign In
Factory Price Universal Laptop Battery Auto Tester
Factory Price Universal Laptop Battery Auto Tester
Supplier Info
[China Supplier]
Contact Person : Mr. Cheng Gary
Tel : 86-755-83107832
Fax : 86-755-83107020
Product Detail
1. It is universal for over 95% brands of laptop batteries. 2. Good quality. 3. Factory Price.

Basic Parameters

Dimensions: 201 x 99 x 35 mm

Weight: 333g

Adapter    Input: AC 100 ~ 240 V   Output: DC 24V 2.65A

Display mode

Segment LCD with white backlight + LED in red and green

Function Introduction

Charge

Active, pre-charge, constant current and constant voltages are the stages of charging mode. The initial charging mode depends on the battery voltage, so active and pre-charge don't happen to every batteries. For charging mode and current, please refer to the paragraphs of charging mode and charging current on page 2 & 3.

Tester will stop charging if one of the conditions below was met.

1) Remaining capacity  ≥ 99% & current intensity = 0

2) Remaining capacity = full charge capacity

3) Current intensity reduce to end charge current when constant voltage charge

4) Remaining capacity reach up the set value

Discharge

Constant current discharge for double loads

Inner load: 0 ~ 1000mA, adjustable continuously via Battery Manager

External load: 0mA, 500mA, 1000mA, 1500mA, 2000mA, five gears with dip switches offered

Tester will stop discharging if one of the conditions below is met.

1) Remaining capacity ≤set value

2) Voltage ≤set value

3) Current intensity reduce to zero

Remarks:

Many batteries can not measure exact current intensity, which cause an else current value appears after you set a value. However, the actual discharging current is the same with your set value.

Test

Testing time is 12 seconds and the purpose is to check both the charging and discharging performances. After finishing test, LED flickers with green color and LCD reports the test result.

Normal:              Test           OK            Shown on LCD

Abnormal:            Test           NG            Shown on LCD

Possible causes and solutions for the abnormal:

1) Cause: battery voltage is too low to discharge

   Solution: try to charge the battery to raise voltage

2) Cause: remaining capacity is too full to charge any more

   Solution: try to discharge the battery to reduce the remaining capacity

3) Bad contact of battery connecting wires

4) Damaged battery

5) Tester trouble

Capacity Correction

The battery capacity value in the battery management chip will different from the actual capacity after a battery goes through many recycling cycles. It will affect the use of the battery when the difference reaches a certain degree. Capacity correction is to deep discharge a battery and then fully charge, which will correct the capacity value in the battery management chip.

Remarks:

Discharging current can be set via Battery Manager. Deep discharge will cause a battery losing communication with tester, so battery dropping phenomenon may happen in the discharging process if the end capacity and voltage are set too low. In such a case, active charge will make the battery work again.

50% Capacity

CD50%: charge firstly, and then discharge to 50% capacity

DC50%: discharge firstly, and then charge to 50% capacity

Online Functions

Tester can be connected with master machine via a USB port. Users can monitor, control and set parameters via Battery Manager software in the master machine.

Monitoring

Battery information can be monitored via three windows.

1. Home screen

   Battery bar and brief information can be read on home screen.

2. Battery detail information window

   Show smart battery data in real time and the data can be saved and printed in image format.

3.  Battery graph window

   Voltage, current and capacity are traced in curves.

Control

Battery Manager can control slave machine completely. Right-click menu on the battery bar includes the related commands.

Attention

All the functions of charge, discharge, capacity correction and 50% capacity are comply with the charging discharging conditions, which are showed on function introduction paragraph in page 4 & 5, so parameters should be set reasonably. Especially, deep discharge will cause a battery losing communication with tester.

Others

1. Active cooling

2. Active batteries of zero voltage

   When a battery is deep discharged, the discharge protection circuit will start up and the voltage in the battery connector will become zero voltage. In this case, an appropriate voltage should be supplied to active the battery.

3. Battery identification

Battery information can be read from battery management chip after establishing communication.

4. Intelligent protection

   Against over-current, over-voltage, over-charge, over-heat and short circuit.

5. Fan

   Discharging mode: fan startup

   Other modes: fan startup when temperature above 48°C

                Fan stop working when temperature below 40°C

6. Trouble alarm

   LED flickers in red color and current command stops when one of the conditions below happen.

   1). There is not current for around 50 seconds when charge.

   2). There is not current for around 25 seconds when discharge.

   3). Charging time is above 8.8 hours.

   4). Discharging time is above 9.9 hours.

   5). Suitable for almost all laptop batteries, above 95%

Structure

Accessories

1).1 * adapter

2). 1 * USB cord

3). 1 * CD

4). 13 * connectors

5). 10 * cables

6). 10 * jumpers

7). 1 * load

 

Factory Price Universal Laptop Battery Auto Tester

Related Products
Ads by Google

Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.