Welcome to ECOL - Join Free - Sign In
1kw solar system for home
1kw solar system for home
Supplier Info
[China Supplier]
Contact Person : Ms. Huang Karen
Tel : 86-755-23313352
Fax : 86-755-23313353
Product Detail
1).1kw solar system for home; 2).70A automatic 3-stage battery charger; 3).3:1 surge ratio; 4).Generator compatible;

1kw solar system for home

 

Key features:

 1. Front panel LED indicators and adjustable switch selectors2. Selectable settings for flooded lead acid, gel, or absorbed glass mat (AGM) batteries3. 70A automatic 3-stage battery charging (bulk, absorption, and float) for increased performance4. Low battery, overload, and high battery, over temperature protection circuitry5. Fast switching (grid to battery and battery to grid) for backup power6. Low idle current (less than one watt) conserves energy when no loads are present7. Durable construction for long life under extreme environmental conditions8. Simplified controls with a snap-on cover that protects settings from being accidentally changed9. Better thermal performance allows full output power to 50°C (122°F) without de-rating10. 3:1 surge capability starts more difficult loads and handles overload conditions reliably11. Circuit boards are conformably-coated to protect them from corrosion for longer life & improved reliability12. Durable powder coated, corrosion resistant steel chassis13. Generator compatible 

Technical specifications:

General specifications:

Input wave form:

Sine wave(Utility or generator)

Nominal voltage:

120VAC

230VAC

Low voltage trip:

90V+/-4%

184V/154V+/4%-

Low voltage re engage:

100V+/-4%

196V/164+/-4%

High voltage trip:

140V+/-4%

253V+/-4%

High voltage re engage:

135V+/-4%

243V+/-4%

Max input AC voltage:

150VAC

270VAC

Nominal input frequency:

50Hz or 60Hz(Auto detect)

Low frequency trip:

47Hz for 50Hz, 57Hz for 60Hz

High frequency trip:

55Hz for 50Hz, 65Hz for 60Hz

Output wave form:

(Bypass mode) same as input

Overload protection:

Circuit breaker

Short circuit protection:

Circuit breaker

Transfer switch rating:

30 amp or 40 amp

Efficiency on line transfer mode:

95%+

Line transfer time:

10 ms typical

Bypass without battery connected:

Yes

Max bypass current:

30 amp or 40 amp

Bypass over load current:

35 amp or 45 amp: alarm

Inverter specification/output

Output wave form:

Pure sine wave or quasi sine wave

Output continuous power watts:

1000

2000

3000

4000

5000

6000

Output continuous power VA:

1000

2000

3000

4000

5000

6000

Power factor:

0.9-1.0

Nominal output voltage rms:

120/230VAC

Output voltage regulation:

+-/10% rms

Output frequency:

50Hz+/-0.3Hz or 60Hz+/-0.3Hz

Nominal efficiency:

>88%

Surge ratings:

3000

6000

9000

12000

15000

18000

Short circuit protection:

Yes, fault after 10 secs

Inverter specification/input:

Nominal input voltage:

12V

24V

48V

Minimum start voltage:

10V

20V

40V

Low battery alarm:

10.5V

21V

42V

Low battery trip:

10V

20V

40V

High voltage alarm:

16V

32V

64V

Power saver:

Below 25 watts when enabled

Power saver:

Same switched on/off on remote

Charger mode specifications:

Input voltage range:

95-127VAC

194-243VAC/164-243VAC(W)

Output voltage:

Dependent on battery type

Charger current:

35A/70A

Battery initial voltage for start up:

0-15.7V for 12V(*2 for 24V; *4 for 48V)

Over charger protection shutdown:

15.7V for 12V(*2 for 24V; *4 for 48V)

Charger curves (4 stage constant current) battery types

4 steps digital controlled progressive charge

Battery type:

Fast V

Float V(*2 for 24V; *4 for 48V)

GEL U.S.A.

14.0

13.7

A.G.M. 1

14.1

13.4

A.G.M. 2

14.6

13.7

Sealed lead acid

14.4

13.6

GEL Euro

14.4

13.8

Open lead acid

14.8

13.3

Calcium

15.1

13.6

De-sulphation

15.5 for 4 hrs

Remote control/RS232/USB

Yes, optional

Size: in mm

1000/2000/3000 model: 442*218*179 mm3

4000/5000/6000 model: 598*218*179 mm3

Net weight:

1000

2000

3000

4000

5000

6000

18Kg

20Kg

22Kg

35Kg

38Kg

40Kg

 