Ads by Google
Specifications | Unit | Technical Index |
Capacity : 5, 6, 10, 15, 20 kg | ||
Rated Output | mV / V | 1.6 ± 10% |
Zero Balance | % F.S. | ± 1 |
Non - Linearity | % F.S. | 0.05 |
Hysteresis | % F.S. | 0.05 |
Repeatability | % F.S. | 0.05 |
Creep ( 30min ) | % F.S. | 0.05 |
Temperature Effect on Output | % F.S. / 10ºC | 0.5 |
Temperature Effect on Zero | % F.S. / 10ºC | 0.2 |
Input Impedance | Ω | 800 ± 40 |
Output Impedance | Ω | 750 ± 10 |
Insulation | MΩ | > 1000 / 50 VDC |
Recommended Excitation | V | 5 |
Maximum Excitation | V | 10 |
Operation Temperature Range | ºC | - 10 ~ 50 |
Safe Overload | % F.S. | 150 |
Ultimate Overload | % F.S. | 300 |
Cable Size | mm | AWG 26 × 450 |
5kg~20kg Weight load cell for kitchen scales