Specification
Model | CL-HD-A84 |
Moisture Method | Ultrasonic humidifier |
Power consumption | 20W |
Input voltage (Driver) | 100~240V/50~60Hz |
Water tank | 0.6L |
whisper-quiet operation | Noise: <35dBA |
Function | moisture control setings |
Protection | Auto shut-off when water run out Low water indicator |
Max mist volume | 200ml/h |
Applicable for room size | 10m² |
Carton Size | Color box:125*125*3900mm Outer carton:635*260*405mm |
Carton Specification | 10pcs/ carton |
Operating Precautions
l Do not add hot water of above 40°C to the water tank and water bath to avoid discoloration or distortion.
C,please empty the water tank and water bath,lest the icing of water should damage the components.
l Do not place metals,chemicals and detergents into the water bath,otherwise there might be poor atomization.
l When there is much water in the water bath, do not move it about,otherwise water might oveflow and flow into the body to cause troubles.
l Do not put the unit at a place with strong light or direct hot air radiation.
l Do not place the unit at an airport and try to keep it away from furniture and electric appliances.
l When the unit is not to be used for a long time,please cut off the power and unplug the plug(this unit does not have to be grounded).
l Never pour out the water remaining in the water bath without the power turned off,otherwise the transducer will be burned out immediately.
l When the water tank is fully loaded,the unit can operate for 7-12 hours contimuously without replenishment.
Safety Precautions
l Do not turn on the plug woth a wethand,otherwise there might be the risk of electric shock.
l When the body is inclined,please handle this with the power cut off.
l Do not touch the transduction piece upon starting,otherwise you will have the feel of pain.
l Do not disassemble the unit without cutting off the power to avoid an electric shock..
Keep in Mind:
a. Never touch the oscillating transduction piece with a sharp hard tool.Clean it with wet cloth only.
b. Do not wipe the surface with cloth dipped with chemical solvent,gasoline,kerosene or pplishing powder.
c. Do not clean the unit with any detergent,preferably use clean water.
d. During cleaning,avoid water entryinto the body,lest the internal electric components should become damp and faulty.
Common Troubleshooting Method
Abnormal symptom | Cause | Handling |
Indicator not illuminated,no air,no fog | The power plug is not properly plugged The power switch is not truned on | Plug the power plug properly Turn on the power switch |
Indicator illuminated,with air,no fog | There is no water in the water tank The automatic constant humidity knob is not turned on The water level float cap is not held down | Top up the water tank Turn the automatic constant humidity Knob clockwise Hold down the water level float cap |
Spray with odor | New unit The water in the tank is not clean | Open the water tank Place at a shade for 12 hours Clean or replace the water tank |
Indicator illuminated,no air,no fog | The water level in the water bath is too high | Pour out some water in the water bath Screw down the water tank cover |
Small fog output | There is scale formation on the transducer The water is dirty or has been stored too long | Clean the transducer Replace with clean water |