Welcome to ECOL - Join Free - Sign In
Split Double Power Automatic Transfer Switch
Split Double Power Automatic Transfer Switch
Supplier Info
[China Supplier]
Contact Person : Ms. Chen Ruru
Tel : 0086-577-61666833
Fax : 0086-577-61666832
Product Detail
1)splited controller can be installed at ats panel 2)Special in Middle East,South Africa,American 3)Export for 7 years

Split Double Power Automatic Transfer Switch YES1-125N 1) Rated current :40,63,80,100 125A

2) Pole number: 2p, 3p, 4p3) Rated working voltage: AC 240V/415V, 50/60Hz

General

Automatic switch and its corresponding intellectual displayer ,which are mainly used in such sites as high-rise building, post & communication, coal mines, vessels, military establishments,industrial streamlines which need the uninterrupted power. Under the inevitable trend of dramatic increasing demand for municipal power, they can more satisfy the higher requirements for the power utilization reliability.They are designed in a whole compact body, and the electrical-mechanical interlocking ensures that the main backup power supplies cannot be closed simultaneously. The position of both power supplies is in switch-off state designed with the isolation function. The disjunction current is the instant exciting mode.

Standard 1.International Standard:1)IEC60947-1(1998)<Low Switch Voltage Equipment and Control Equipment, part one :General Rules>.2)IEC60947-3(1999)<Low Switch Voltage Equipment and Control Equipment, Switch, Isolator, Isolation switch, and Combined Electric Equipment of Fuses>.3)IEC60947-6(1999)<Low Voltage Switch Equipment and Control Equipment Multi-Function-Switch Automatic Transfer Switch Electrical Device>. 

2.National Standard:1) GB/T 14048.1-2000 <Low Switch Voltage Equipment and Control Equipment, General Rules>.2) GB/T 14048.3-2002 <Low Switch Voltage Equipment and Control Equipment, Switch, Isolation ,Isolation switch, and Combined Electric Equipment of Fuses>.3)GB/T14048.11-2002 <Low voltage switchgear and control gear part6-1:Multiple function equipment automatic transfer switching  equipment>.

Operation Environment :1.Height above sea level does not exceed 2,000m;2.Ambient temperature is not higher than 40°C and not lower than below 5°C;3.Relative humidity is not larger than 95%;4.No explosive dangerous medium environment;5.No rain and snow attack environment;(Note: if the load isolation switch is expected to be used in the condition that the ambient temperature is higher than +40°C or is lower than -5°C-45°C,customers should inform to the manufactory.)  

Parameters

rated current(A)40,63,80,100,125
working current(A)3.5
rated tolerance current in short time(KA)5
mechanical life (times)8000
electrical life(times)3000
poles optional2/3/4p
N.W.(KGS)4/4.5/5.5
working cycle(s/times)10

Quality Control

1)product performance accurately meets above national and international standards.

2)All the components are aged and selected strictly, the finished products are continuously aging for 24hours at high temperature condition;

3)EMC /life enduring/temperature rising /character and comprehensive testing equipments are configured to meet relative test and guarantee the product quality. 

4)During the production process ,ISO9001 production and management system is strictly carried;