MST-60 Automatic battery Voltage Regulator
Good quaity with competitive price
one year quality warranty
quick delivery
tel: +86 1500 133 6788
Features:
1. Regulates output voltage and current.
2. Protects from over-voltage, over-current and over-temperature with voltage and current number reading indicators on the equipment and over-temperature indicator.
3. Enables automatic and safe vehicle ECU programming.
4. Prolongs battery lifespan and Enables battery being charged to the full if it’s used for battery charge.
5. Can be used unattended and fully automatically
Range of application
1.Cars: regulate battery voltage during programming for BENZ & BMW etc. premium cars
2. Electromotor bike
3. Electrics screen
4. SPC exchange
5. Broadcast transmitter
6. Communication work station
7. UPS
8. Battery and Power supply system
Main parameters
1. input voltage: AC220V±15%, or AC110V±15% (order needed)
2. output voltage adjustable range: 14V
3. output current adjustable range: 60A
Common Specification
Nominal Output Voltage | 12V | Max. Output Current | 104A |
Max. Output Power | 1248W | Efficiency (typ) | 80% |
Input Current (typ) | 7/0A:230VAC at 1248W | Output Voltage Range | fixed |
Input Voltage Range | 200-265VAC (47-63Hz) | Input Voltage Accuracy | 11.88-12.12V |
Max. Ripple & Noise | 240mV | Max. Line Regulation | 60mV |
Max. Load Regulation | 240mV | Over Current Protection | 105-112A |
Over Voltage Protection | 16.2-18.6V | Remote On/Off | available |
Remote Sensing | Possible (Max 1V for total drop) | Over Output Power Protection | More than 1260W |
Inrush Current | 40A max (ta=25’c cold start) | Hold-up time | 10ms |
PFHC | Built to meet EN61000-3-2. PFHC range: 200-255VAC | Leakage Current | Less than 0.95mA |
Power Factor | 230VAC:0.95 at 1248W | Operating Temperature | 0-50 ‘c |
Operating Humidity | 30-90%Rh (No Dewdrop) | Storage Temperature | -30-+85’c |
Storage Humidity | 10-90%Rh (No Dewdrop) | Cooling | Forced Air by Blower Fan |
Withstand Voltage | Input-FG:1.5kVAC(20mA) for 1 min. Input-Output:3kVAC (20mA) for 1 min. | Isolation Resistance | More than1000M^ Output-FG: 500VAC at 25’c, 70%Rh |
Vibration | At no operation, 10-55Hz (Sweep for I min) 19.6m/s2 constant, X,Y,Z, 1 hour each | shock | Less than 196.1m/s2 |
Safety Standard | Built to meet UL60950,CSA60950-00(c-UL), EN60950 (SEMKO) | Conducted Emission | Built meet EN55022-A, VCCI-A |
Immunity | Built to meet EN61000-4-2 Level4, EN61000-4-3, EN61000-4-4 Level4, EN61000-4-5 Level3 | Radiated Emission | Built meet EN55022-A, VCCI-A |
Size (w*H*D) | 175.5m*63mm*279mm (refer to Outline Drawing) | Weight | 3.4kg |