Verabar flow sensor
Verabar flow sensor
Supplier Info
[China Supplier]
Contact Person : Mr. peng franz
Tel : 86-29-85690252,88608386
Fax : 86-29-88882045
Product Detail
1.measure the flow of liquids,gas and steam 2.convenient for setup and repair 3.low operation cost, no pressure losses,

Feature

The XYBAR Flow meter make it possible to measure the movement of gases, steam

and liquids through differential Pressure regardless of the properties of substance.

1.Suitable for measuring the flow of liquid and gaseous media

2.It consists of no moving parts and has no pressure losses

3. Pipe diameters from 15 to 12.000mm

3. Pipe diameters from 15 to 12.000mm

4.Excellent long-term accuracy

5.Convenient for setup and repair, low operation cost

6.Can adopted differential pressure transmitter, temperature

Transmitters and flow integrating instrument are produce in

Any factory to make up various type of low meter

7. Operating temperature: -100°C~500°C

8.Operating pressure: 0 to 25 Mpa

Special design

Sensor Parts ;

The sensor is composed of detected rod, pressure tapping and guide rod, which pass across internal pipe and perpendicular to axis of pipeline.A number of pressure measuring holeson face flow side of the rod can measure the total average pressure, and on the back and side of the stream surface have static pressure measurements holes, respectively, guided by the main connecting pipe and the static pressure pipe .According to differential pressureof the total pressure and the pressure to calculate flow through the pipe.

Transmitter parts;

The Flowmeter transmitter is composed of sensors, guiding pressure accessories and differential pressure transmitter, pressure transmitter, flow integrating instrument and other supporting components. The Flowmeter

flow sensor can make up varied types of flowmeter with differential pressure transmitter, pressure transmitter, temperature transmitters, and temperature transmitter manufactured by our company. It can also be adopted differential pressure transmitter, pressure transmitter, temperature transmitters and flow integrating instrument are produced in any factory, to make up various types of Flowmeter.

Installation requirements

The I-sensors, the detect rod and a section of pipe has been welded together, the sensors must be installed in the direction of the fluid flow.Technology requirements of the pipeline diameter and the diameter of the sensor are in line, or at least in the upper reaches of the pipe above the required length of the sensors within the framework of the pipe axis and the axis formed angle as far as possible to zero.

Other types of sensors that the detect rod is inserted in the process piping, installation, besides the total pressure tapping should be the direction of flow velocity, must ensure that the sensors detect rod perpendicular to the process pipeline, which allows the location of the angular pressure deviation as shown in Figure Six.

The angle between the center of sensors total pressure tapping and pipe axis should be less than 7 °.

The detect rod of sensors along the pipeline diameter under the direction of insertion in the end, the deviation angle of less than 7 ° (Figure 6)

The vertical pipe sensor can be installed on the horizontal pipe along the pipeline circumference of 360 in any location; the high and low guiding pressure pipe should be installed in the same plane.The horizontal installation of the pipeline measuring, as shown in the Figure 7(a);When measure the gas, the lower side to tilt the installation as shown in Figure 7(b);

 when measure the steam, it should be installed horizontally as shown in Figure 7(c).