Ads by Google
power plant
YuDong -- British PerkinsYP1350 diesel generating sets technical paameters | |
Genset technical parameters | |
Genset model | YP1350 |
Shape dimension/ L x W x H mm | 5270×2190×2450 |
Weight(dry weight) kg | 10950 |
Normal power kVA/kW | 1687.5/1350 |
Standby power kVA/kW | 1812.5/1450 |
Rated voltage V | 400/230 |
Output frequency Hz | 50 |
The steady-state voltage adjustment rate % | ±1 |
Voltage fluctuation rate % | ≤0.5 |
Frequency flutuation rate % | ≤0.5 |
Load mutations frequency stability of time(S) | ≤3 |
Load mutations voltage stability of time(S) | ≤2 |
Wiring way | Three-phase four-wire |
Control system | Microcomputer control system |
Vibration absorber system | High elastic rubber shock absorbers |
Noise (dB)(1meter) | 111 |
Engine | |
Engine model | 4012-46TAG3A |
Type | Sixteen-cylinder, inline, turbochareged |
Oil type | API CD 15W-40 and above |
Fuel consumption rate g/kwh | 212 |
Oil consumption g/kwh | Fuel 0.5% |
Lubricating oil capacity L | 212 |
Starting mode | DC 24V electric start |
Speed regulation | Electricity adjustable |
Type of cooling | Closed recirculation cooling |
Fan power loss kW | 62 |
Average effective pressure kPa | 1920 |
The piston velocity m/s | 9.5 |
The total capacity of cooling fluid L | 177 |
Inlet flow m3/min | 114 |
Exhaust flow m3/min | 340 |
Exhaust temperature °C | 520 |
Compression ratio | 13:01 |
Combustion way | Fuel injection |
Cylinderbore/stroke mm | 160/190 |
Single cylinder displacement L | 3.82 |
The flywheel interface size (the flywheel shell/flywheel) | SAE00/18 |
Generator | |
Model(single bearing) | MX-1350-4 |
Shape dimension/L x W x H mm | 1930×960×1300 |
Weight kg | 3540 |
Power(normal/standby) kW | 1350/1450 |
Excitation system | Brushless motivated |
Short-circuit current capacity | 300%(3In):10s |
Protection grade | IP21 |
Winding pitch | 2/3 |
The steady-state voltage adjustment rate % | ±0.5% |
Recovery time s | ≤0.5 |
Wave form deviation factor THD | ≤5.0% |
Telephone harmonic factor THF | <2% |
Telephone disturbance factor TIF | <50 |
Control system | |
Control module | Deepsea5110(automatic type) |
Display content | Exchange phase / Line voltage, three-phase currents, the battery voltage, frequency, hydraulic, water temperature, runtime, display alarming fault, engine speed |
Main function | Low speed/speeding alarm, charging failure, abrupt stop input, low hydraulic alarm, high temperature alarm, failed to start,there are three can be set output which is derived from start |