Welcome to ECOL - Join Free - Sign In
Measuring counter
Measuring counter
Supplier Info
[China Supplier]
Contact Person : Ms. Ho Cathy
Tel : 86-512-66877225
Fax : 86-512-68416875
Product Detail
1. Reliable 2. Easy-to-use machine; 3. Portable, 4. Six size channels, 5. Built-in printer

Airborne Particle Counter CLJ-BII counts airborne particles in six different size ranges simultaneously. Count data is displayed on the front-panel as total number of particles (cumulative count). The printout shows cumulative count data for each size range.FEATURES:

0.1 cfm (2.83 lpm) flow rate2 counting modes (Auto/Manual)Six particle-size channels (0.3, 0.5, 1.0, 3.0, 5.0, 10µm)Date and time displayFederal Standard 209E Calculation Built-in Printer,  Multiple print-modeData conversion (ft3 and m3)Data storage

APPLICATIONS

• Monitor and verify cleanrooms

• Test filters in place

• Track down particle sources

• Monitor:

Laminar Air Flow and biohazard benches

Cleanroom laundries

HVAC systems

Computer rooms

Food and beverage packaging

Hospitals: Pharmacy and surgery

Indoor Air Quality (IAQ)

Aerospace Assembly

Medical Device Assembly

Automotive: Paint spray booths

Filter performance

Specification:

Model

CLJ-BII

Flow rate

0.1 cfm (2.83 lpm)

Sensitivity

0.3µm

Self Clean Time

≤10min

Operating Time

8h

Output

Built-in Printer

Environment Operating

Temperature 10~35°C,Relative Humidity ≤75%

Power Supply

220V±10%,50Hz±2Hz

Size Channel

0.3,0.5,1,3,5,10(µm)

Sample Period

1min~10min

Clock

Date and Time

Counts Data

Total Counts, Counts/ft3 and Counts/m3

Data Calculation

Federal Standard 209E Calculation

Light source

Laser diode (30,000 hours mean time between failure)

Power Rating

35W

Dimension

225X1203300(mm)

Weight

5.5Kg