FLUKE 773 Millamp Process mA Clamp Meters F-773 0-24mA Loop Calibrators
FLUKE 773 Millamp Process Clamp Meters0-24mA Process Clamp Meters250 aa HART resistor for mA sourcefluke mA clamp meters
773 mA Clamp Meter features: Best in class 0.2 % accuracy0.01 mA resolution and sensitivityMeasure 4 to 20 mA signals without ”breaking the loop” Measure mA signals for PLC and control system analog I/ODual backlit display with both mA measurement and percent of 4 to 20 mA spanMeasurement Spotlight illuminates hard to see wires in dark enclosuresDetachable clamp with extension cable for measurements in tight locationsMeasure 10 to 50 mA signals in older control systems using the 99.9 mA rangeAutomatically change the 4 to 20 mA output for remote testingPower saving features, auto-off, backlight timeout extend battery lifeHold function captures and displays changing measurementsMeasure 4 to 20 mA signals with in-circuit measurementSimultaneous mA in-circuit measurement with 24V loop power for powering and testing transmittersSource 4 to 20 mA signals for testing control system I/O or I/PsmA output linear ramp or 25% step outputAutomatically change the 4 to 20 mA output for remote testingDC voltage measurement to verify 24V power supplies or voltage I/O signalsSource DC voltage to test input devices that accept a 1-5V or 0 to 10V signalsVoltage output linear ramp or 25% step outputAutomatically change the voltage output for remote testing
Functional Specifications | |
mA measurement (Measured by clamp) 771/772/773 | Resolution and Range: 0 to 20.99 mAAccuracy: 0.2%+2 countsResolution and Range: 21.0 mA to 100.0 mAAccuracy: 1% + 5 counts |
mA measurement (Measured in series with test jacks) 772/773 | Resolution and Range: 0 to 24.00 mAAccuracy: 0.2% + 2counts |
mA source (Maximum mA Drive: 24 mA into 1,000 ohms) | Resolution and Range: 0 to 24.00 mAAccuracy: 0.2% + 2counts |
mA simulate (Maximum voltage 50 V dc) | Resolution and Range: 0 to 24.00 mAAccuracy: 0.2% + 2counts |
Voltage source (2 mA maximum drive current) | Resolution and Range: 0 to 10.00 V dcAccuracy: 0.2% + 2counts |
Voltatge Mesaure | Resolution and Range: 0 to 30.00 V dcAccuracy: 0.2% + 2counts |
Attn:Ms Rene Chow
Trade Manager:cn1001604516
Skype:tracy884404
Tel:0086-136-3169-7416
QQ:862457367
( function(){ var aBigImageSrc = [ 'http://i00.i.aliimg.com/photo/v0/757700112_1/FLUKE_773_Millamp_Process_mA_Clamp_Meters.jpg' , 'http://i00.i.aliimg.com/photo/v0/757700112_2/FLUKE_773_Millamp_Process_mA_Clamp_Meters.jpg' , 'http://i00.i.aliimg.com/photo/v0/757700112_3/FLUKE_773_Millamp_Process_mA_Clamp_Meters.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); FLUKE 773 Millamp Process mA Clamp Meters F-773 0-24mA Loop Calibrators