Table type Ionizer Air Blower
It is designed as the theory of alternating current electrostatic eliminator.Apply to eliminate electrostatic in a limited distance, convenient to remove and install.The ionizing air volume can be adjusted, including high voltage generator.
Specification | ||||||
Operating Voltage | 110V/60HZ OR 220V/50HZ | |||||
Current Consumption | 0.25A OR 0.12A | |||||
Operating Temperature | 0~50 degrees | |||||
Size | 90mm(L)170mm(W)260mm(H) | |||||
Weight | 3.3Kg | |||||
Air Volume | 45110CFM | |||||
Ion Balance | 0V10V | |||||
Air Coverage | 40cm x 60cm | |||||
Decay test Results | ||||||
Testing Conditions | Test voltage1KV-100V Operating Voltage110/220V Temperature22 Test Humidity75%RH | |||||
Distance | 300mm | 600mm | 900mm | |||
Decay time | Positive | 1.2s | 2.5s | 3.9s | ||
Negative | 1.3s | 2.6s | 4.1s | |||
Offset voltage | Positive | 8V | 5V | 4V | ||
Negative | -7V | -6V | -3V |